B48100 ESS Unit User Manual
7
1. If the host is the latest B48100 battery with DIP switch:
(1) The communication cable from the host CAN IN to the inverter comm port should be the
correct one.
(2) When the battery works with GOODWE
、
Solis
、
LUX
、
Sofar
、
DEYE
、
VICTRON
、
IMEON
、
Infinisolar
、
Sungrow
、
SMA
、
RENAC
、
DELIOS
、
SAJ(CAN Comm)
,
Growatt HVM-
ES/WPV(CAN port),before starting the battery,you need put the host DIP switch "# 3" to the
"ON" position (to the top), then turn on the batteries.
(3) If the battery communicates with the Axpert-king,Axpert-VMIII,Growatt SPH/SPA(CAN
comm)
、
GMDE
、
Saj(485 comm), turn the host DIP switch "#2" to "ON" position.
(4) If the battery communicates with the Growatt SPF HVM-P/ES/WPV by RS485 port, turn
the host DIP switch "#2" and "#3" to "ON".
(5)
If the battery module is in communication with the ICC by 485 communication, turn the
host DIP switch "#1" and "#4" to "ON".
the DIP switch of the slaves need to turn the
“
#4
”
to
“
ON
”
.
(7) The DIP switch of the slaves no need to be changed.
(8) If the energy storage system has only one B48100, it is the host itself, and still follow the
above steps.
Note: For more information of matching inverter brands, please subject to the latest
document
<The list of compatibility between Dyness ESS and Inverters >.
Caution
:
The DIP switch mode in case (5),1001 is only for ICC(a special commnunication
device of some no-
communication inverter), it’s a specia
l firmware in BMS, different from
general firmware, so if customers want to use ICC, please contact Dyness to confirm.