Additional components
Power Transfer Switch
A Power Transfer Switch must be installed for switching over from an external power source
(e.g. shore power 230V) to on board power source, DYNAWATT. Fig. 7.
List of Parts Supplied
1. Generator is supplied with 6m cable
2. Control unit
a. 2 pc. attachment brackets (loose)
b. 4 pc. M6 x 10mm attachment screws for brackets (on the back of Control Unit)
c. EMI fitting for the generator cable (on the front side of CU)
d. Fitting for the 230V cable (on the front side of CU)
3. Remote control with 5 or 10 m cable (available as an option)
4. User manual
Parts Required, Not Supplied
1. Three-conductor power cable, min. 3x1.5mm2
2. Vehicle-specific installation sets available on request.
3. 4 pc. attachment screws for the Control Unit
Generator Speed and Available Power
Calculation Sheet
(Note: Measure the belt pulley external diameter)
Generator speed
Belt pulley dia. generator side:
Ra = .......... mm
Belt pulley dia. motor side:
Rm = ......... mm
Motor speed idling:
nL = ........... rpm
Motor speed max.:
nM = .......... rpm
Belt pulley transmission:
iR = Rm : Ra= .............
Generator idling rpm:
NA
Idling
= (iR) x (nL) = ........ rpm
Generator max. rpm:
Na
max
= (iR) x (nM) = ........ rpm
Available output in watts
Read from the Curve of Figure 21
Power at engine idle speed (NA
Idling
) .................. Watt
Minimum speed for full load
.................. rpm
7
Summary of Contents for 4000
Page 1: ...4000 User Manual Installation and Operation L100 01E 05 99 230 V POWER SYSTEMS ...
Page 17: ...17 Figure 1 Generator ...
Page 18: ...18 Figure 2 Controllunit ...
Page 19: ...19 Figure 3 Remote Control ...
Page 20: ...20 Figure 4 Generator Performance Curve ...
Page 21: ...21 Figure 5 Preparing cables ...
Page 22: ...22 Figure 6 Connecting Terminals ...
Page 23: ...23 Figure 7 Power Transfer Switch ...