230V Connection
Prepare cable as shown in Figure 5 and pull it through the plastic screw connection
into the Control Unit. Attach cable to the output filter terminal clamp. Ensure secure fit.
Minimum recommended cable size: 3x1.5mm2. (Cable up to 4mm2 possible)
230V connection terminal function:
Terminal No.
Function
Cable colour
L
Phase
Brown
N
Neutral
Blue
E
Earth
Yellow/Gree
n
Starting the System
The following must be checked before starting the system:
- that the generator cable has been correctly installed
- that the V-belt tension has been correctly set
- that all installation screws have been tightened
- that the cables have been connected to the correct terminals and are securely clamped.
- when unit is switched ON, check if fan is operating
Troubleshooting
The system doesn’t work
Check the condition and tension of the V-belts.
Check the cable and terminal connections.
LEDs on the remote control faint
Check to see whether cable 4 (+) and 5 (-)
but no power
have been connected the wrong way
around or whether generator must be
magnetized again. See Page 14.
Increase Speed Light comes on
V-belt slipping, check tension and condition,
adjust tension.
15
Summary of Contents for 4000
Page 1: ...4000 User Manual Installation and Operation L100 01E 05 99 230 V POWER SYSTEMS ...
Page 17: ...17 Figure 1 Generator ...
Page 18: ...18 Figure 2 Controllunit ...
Page 19: ...19 Figure 3 Remote Control ...
Page 20: ...20 Figure 4 Generator Performance Curve ...
Page 21: ...21 Figure 5 Preparing cables ...
Page 22: ...22 Figure 6 Connecting Terminals ...
Page 23: ...23 Figure 7 Power Transfer Switch ...