Monitor Setup page
Fig. 48: AIR Control software – Monitor setup page
Use the Setup page to send test signals and configure
basic parameters for the selected monitor.
The following setup parameters are available for all AIR
monitors.
Test
Click the Test button to generate a test signal. To stop
the test signal, click this button again.
Please note that the test signal will be generated at the
currently set level.
Monitor Task
Use the Monitor Task parameter to specify the task
(e.g. Left Front or Right Front) for the selected monitor
in the current setup.
Room position
Use the Room position parameter to specify the room
position of the selected monitor. See “Monitor positions”
on page 52.
Test Signals
Use the Test Signals parameter to specify the test sig-
nal type/source for this monitor. You can choose be-
tween Pink Noise and 96 kHz EQ out.
When you set Test Signals to Pink Noise and click the
Test button, the speaker will output pink noise at the
currently set level.
When you set Test Signals to 96 kHz EQ out and click
the Test button, the Master speaker will output an AES/
EBU signal on its
TC link output.
This test signal can
be used to check the EQ settings using a measuring
device connected to the TC Link port using an RJ45-
AES/EBU cable.
X-Curve
Use the X-Curve parameter to select the X-Curve for
the selected monitor. See “X-Curves” on page 58.
Delay
Use the Delay parameter to specify a delay for the sig-
nal assigned to this monitor. See “Delaying monitors”
on page 119.
Calib Level
Use the Calib Level parameter to calibrate each moni-
tor. See “Calibrating the main monitors” on page 57
and “Calibrating the subwoofers with the main moni-
tors” on page 61.
Ref. Level
Use the Ref. Level parameter to set the reference level
for each monitor.
Treble
Use the Treble parameter to set the amplification or at-
tenuation for the treble band of the two-band shelving
EQ in each monitor
Bass
Use the Bass parameter to set the amplification or at-
tenuation for the bass band of the two-band shelving
EQ in each monitor. For more information, see “Equal-
izing the monitors” on page 56.
The following setup parameters are only available for
AIR subwoofers:
LFE Gain
Use the LFE Gain parameter to set the LFE channel
gain for the selected subwoofer. See “LFE Gain (sub-
woofer parameter)” on page 61 and “The LFE Chan-
nel” on page 118 for background information on LFE.
Phase
Use the Phase parameter to set the signal Phase for
the selected subwoofer. See “Calibrating the subwoof-
ers with the main monitors” on page 61.
Pol 180deg
Use the Pol 180deg parameter to reverse the polarity of
the signal during calibration for the selected subwoofer.
See “Polarity (subwoofer parameter)” on page 61.
Summary of Contents for AIR 15
Page 1: ...Dynaudio Professional AIR Reference manual 2014 09 28 ...
Page 7: ... Before you begin Dynaudio Professional AIR reference manual 2014 09 28 4 Before you begin ...
Page 10: ... The AIR concept Dynaudio Professional AIR reference manual 2014 09 28 7 The AIR concept ...
Page 32: ... AIR setups Dynaudio Professional AIR reference manual 2014 09 28 29 AIR setups ...
Page 66: ... AIR Remote Dynaudio Professional AIR reference manual 2014 09 28 63 AIR Remote ...
Page 85: ... Cables Dynaudio Professional AIR reference manual 2014 09 28 82 Cables ...
Page 88: ... Presets Dynaudio Professional AIR reference manual 2014 09 28 85 Presets ...
Page 90: ... Reset procedures Dynaudio Professional AIR reference manual 2014 09 28 87 Reset procedures ...
Page 92: ... Error messages Dynaudio Professional AIR reference manual 2014 09 28 89 Error messages ...
Page 94: ... Warranty Dynaudio Professional AIR reference manual 2014 09 28 91 Warranty ...
Page 126: ... Links Dynaudio Professional AIR reference manual 2014 09 28 123 Links ...
Page 128: ... Links Dynaudio Professional AIR reference manual 2014 09 28 125 ...