SEAL KIT
HPW1200/100-440
DETAILS
QUANTITY
V100102700
1.x.x
2104564100
SEAL 150
HYDRAUL/WATER PISTON ASSY
1
1.x.x
2204349100
O-RING 144
SEAL FLANGE ASSEMBLY
2
1.x.x
2104534000
WATER PISTON SEAL, 1T
SEAL FLANGE
2
1.x.x
2104539000
WATER PISTON SEAL, 2T
SEAL FLANGE
2
1.x.x
0409016467
WATER PISTON SEAL, 1T
SEAL FLANGE, WATER CYLINDER
4
1.x.x
0409016482
SEAL ASSEMBLY 70
SEAT, WATER CYLINDER
2
1.x.x
0409016484
SEAT SEAL ASSEMBLY 32
PRESSURE VALVE ASSEMBLY
2
1.x.x
0409016521
SEAL ASSEMBLY 21
PRESSURE MANIFOLD
4
1.x.x
2204339900
O-RING
120
WATER
CYLINDER
2
1.x.x
220422000
O-RING
66
INLET
MANIFOLD 2
1.x.x
2204205120
SEAL
55
ASCENDING
TUBE
2
REPAIR KITS
8
MAINTENANCE
Due to small number of moving parts, in normal operating conditions HPW-pump does not require any other
service, except replacement of sealings or occasionally of water valves, which depends on content of abrasives
in pumping fluid, as well as on cleanliness of hydraulic oil.
Check constantly whether the fluid dropping from pump’s leakage detectors is growing and replace sealing in
proper time to exclude intermixing of hydraulic oil and pumping fluid.
The pressure in hydraulic fluid circuit is considerably high and hydraulic system has to maintain regularly.
Especially couplings, valves and hoses have to be tight and clean as well as kept under constant observation.
Check and fix possible leakages of pressure and hot blowouts immediately avoiding user and bystander injuries.
Prior to any cleaning, inspection and service hydraulic system of your carrier machine must be stopped and all
hydraulic fluid circuits depressurized.
To enable the easy surveillance, pump should be kept clean.
WHEN CARRYING OUT ANY DISASSEMBLING OR REPAIR OF HPW-PUMP, ABSOLUTE CLEANLINESS
MUST BE MAINTANED TO ENSURE RELIABLE AND TROUBLE-FREE OPERATION OF YOUR EQUIPMENT.
HIGH PRESSURE PUMP HPW 1200/100-440
March 2013 JLe