11
TECHNICAL SPECIFICATIONS
PARAMETERS
HPW 1200/100-440
WATER POWER
WATER
FLOW
max
l/min
(gal/min)
100
(26,5)
WATER PRESSURE
max
bar (psi)
1200 (17400)
WATER
TEMPERATURE max
ºC
(ºF)
70
(158)
PUMPING
POWER
max
kW
(hp)
200
(269)
WATER FEED PRESSURE
min-max
bar (psi)
1...16 (1...232)
PRESSURE
RATIO
water/hydraulic
4
SPEED
RATIO
1/min
440
WATER PISTONS
outer diameter
mm (”)
50 (2”)
WATER CONNECTIONS
PRESSURE
LINE
MP
3/4“
Recommended hose length 10m with max. flow
Pipe ID 13mm
SUCTION / FEED LINE
SAE 3000 SAE 2”
SUCTION
HOSE recommendation 2”
WATER FILTER
min.
abs.
μ
m (mesh)
125 (120)
HYDRAULIC CONNECTIONS
PRESSURE
LINE
P
SAE 6000 1 1/4”
RETURN
LINE
T
SAE 6000 1 1/4”
SERVICE LINE
S / CMP
DIN
1/8”
HYDRAULIC FLUID REQUIREMENTS
VISCOSITY
cSt
10 - 200 / optimal 25 - 35
TEMPERATURE max.
ºC
(ºF)
70
(158)
FILTER
RATIO
recommendation um
min.
25
COOLING CAPACITY
recommendation
kW (hp)
35 (47)
HYDRAULIC POWER REQUIREMENTS
HYDRAULIC FLUID FLOW
max.
l/min (gal/min) 440 (116)
OPERATING PRESSURE
Δ
p
bar (psi)
300 (4350)
MAXIMUM
PRESSURE
bar
(psi) 350
(5080)
IDLE
RUN
PRESSURE
bar
(psi)
10
(145)
RETURN LINE PRESSURE
max
bar (psi)
230 (3340)
WEIGHT
kg
(lb)
177
(390)
PRESSURE GAUGE
OPTIONAL
WATER PRESSURE UNLOADER
NOT
AVAILABLE
LS-VALVE
OPTIONAL
HIGH PRESSURE PUMP HPW 1200/100-440
March 2013 JLe