INSTALLATION
NOTE!
Location of P- and T-ports variates between different DYNASET hydraulic
equipment.
Ensure that the hydraulic flow of the base machine is sufficient to run the unit.
At least the minimal flow must be available. READ CHAPTER “10. TECHNICAL
Picture 22: P-line operational hydraulic flow
In case of hydraulic flow being too high. The flow must be reduced either by
dropping down the rotation speed of base machine’s hydraulic pump or using
flow limiter valve. DYNASET PV-SAE priority valve is recommended.
Picture 23: Base machine pumps
Return line must be connected to a hydraulic oil tank in the shortest possible line
in order to keep the return hydraulic pressure under 5 bar in the tank line. T-line is
to be connected directly to the return line of a hydraulic system.
Picture 24: Return line connection