background image

Application Assistance 1.800.234.8731 (847.662.6633)

Page 8

ORDERING INFORMATION

European Sales Representitive

Hengstler GmbH
Uhlandstrasse 49, 78554 Aldingen
Germany
www.hengstler.com

Customer Service:

Tel.: +1.800.873.8731
Fax: +1.847.662.4150
[email protected]

Worldwide Brands:  NorthStar

TM  

•  Acuro

TM  

•  Dynapar

TM

  •  Hengstler

TM

   •  Harowe

TM

WWW.DYNAPAR.COM

Headquarters: 1675 Delany Road • Gurnee, IL 60031-1282 • USA

INNOVATION - CUSTOMIZATION - DELIVERY

Technical Support

Tel.: +1.800.234.8731
Fax: +1.847.662.4150
[email protected]

0  

None

1  

4.5” C-face tether

2  

8.5” C-face tether

3  

Slotted tether (to fit 

standard AC motor 
fan cover)

Not available when 

Code 5 is D,E,F,G, Q, R

4  

Same as 1 w/cover

5  

Same as 3 w/cover

C

  Same as A with 56C 

cover (Single Only)

Available when Code 5 

is D,E,F,G, Q, R

6  

Same as 1 w/dual 

cover

7  

Same as 3 w/dual 

cover

8  

Same as 2 w/ 

180 C-face cover 
(single or dual 
output)

A

  Rod tether

B

  Rod tether with 

ground strap.

D

  Same as B with 

56C cover (Single 
Output)

10 foot Cable Assemblies with MS Connector
108594-0010

     6 Pin MS, Cable Assy. For Use with Single Ended Outputs

108595-0010

     7 Pin MS, Cable Assy. For Use with Single Ended Outputs

108596-0010

     7 Pin MS, Cable Assy. For Use with Differential Line Driver w/o Index Outputs

112123-0010

     6 Pin MS, Cable Assy. For Use with Differential Line Driver w/o Index Outputs

1400635-0010

   10 Pin MS, Cable Assy. For Use with Differential Line Driver with Index Outputs

114448-0010

     10 Bayonet, Cable Assy. For Use with Differential Line Driver with Index Outputs

 109209-0010

    NEMA4 10 pin MS, Cable Assy.  For Use with Differential Lne Driver with Index Outputs

10 foot Cable Assemblies with M23 Connector
108615-0010

     12 M23, Cable Assy. For Use with Differential Line Driver with Index Outputs, CCW

15 foot Cable Assemblies with M12 Connector
112859-0015

     5 Pin M12, Cable Assy. For Use with Single Ended Outputs

112860-0015

     8 Pin M12, Cable Assy. For Use with Single Ended Outputs

112860-0015

     8 Pin M12, Cable Assy. For Use with Differential Line Driver Outputs

0  

6 pin

1  

7 pin

2  

10 pin

3  

12 pin

4  

10 pin bayonet

5  

6 pin+mating

6  

7 pin+mating

7  

10 pin+mating

8  

12 pin+mating

9  

10pin 

mating

A  

0.5m (18”) cable

C  

1m (36”) cable

D  

2m (72”) cable

E  

3m (120”) cable

F  

0.3m (13”) cable with 

10-pin bulkhead  
connector and mate

G  

0.3m (13”) cable

5 pin M12

J  

8 pin M12

Ordering Information

Code 2: PPR

Code 7: Options

Code 1: Model

HS35R 

Heavy-Duty, 

Hollowshaft 
Encoder

Code 3: Bore Size

 
 
 

Code 6: Termination

 

Code 4: Fixing

 

    Code 5: Output Format

0001
0003
0010
0012
0015
0032
0050
0060
0100
0120
0200
0240
0250
0300
0360

Accessory Kits: 
114573-0001

   Tether Kit, 4.5” C-face single point with 3/8” bolt

114574-0001

   Tether Kit, Slotted with T-bolts for standard  

 

       AC motor fan covers

114575-0001

   Tether Kit, 8.5” C-face single point with 1/2” bolt

114591-0001

   Cover Kit, 56C face

114592-0001

   Cover Kit, fan cover

114593-0001

   Dual Cover Kit, 56C face

114928-0001

   Dual Cover Kit, 180C-face

114594-0001

   Dual Cover Kit, fan cover

116233-0001

   Rod Tether only

116233-0002

   Rod 56C face cover (single)

116233-0004 

  Rod grounding strap    

116233-0005 

  Rod grounding strap +5 6C fa ce                   

.                        cover (single) 

0500
0512
0600
0900
1000
1024
1200
1500
2000
2048
2400
2500
3072
4000
4096
5000

0  

6mm

1  

1/4”

2  

5/16”

3  

8mm

4  

3/8”

5  

10mm

6

  12mm

7  

1/2”

8  

5/8”

9  

15mm

A  

16mm

C  

19mm

D  

3/4”

E  

20mm 

F  

7/8”

G  

24mm

H  

1”

J  

1-1/8”

K  

1-1/4”

M  

14mm

18mm

P  

25mm

R  

28mm

0  

ABZ, 5-26VDC push-pull

1  

ABZ, 5-26VDC O/C

2  

ABZ, 5-26VDC O/C w2.2kOhm

 Same as “0” with Extended temp range

  Same as “1” with Extended temp range

K

  Same as “2” with Extended temp range

Not available when Code 6 is H

4  

Differential AB only, 5-26VDC, 5-26VDC out (7272)

5  

Differential AB only, 5-26VDC in, 5VDC out (7272)

A

  Differential AB only, 5-26VDC in, 5VDC out (4469)

C

  Differential AB only, 5-15VDC in, 5-15VDC out 

(4469)

L

  Same as “4” with Extended temp range

M

  Same as “5” with Extended temp range

Not available when Code 6 is 0, 1, 5, 6, or H 

6  

Differential ABZ, 5-26VDC in, 5VDC out (7272)

7  

Differential ABZ, 5-26VDC in, 5-26VDC out (7272)

8  

Differential ABZ, 5-26VDC in, 5VDC out (4469)

9  

Differential ABZ, 5-15VDC in, 5-15VDC out (4469)

D  

Dual isolated outputs, same as “6”

E  

Dual isolated outputs, same as “7”

F  

Dual isolated outputs, same as “8”

G  

Dual isolated outputs, same as “9”

N

  Same as “6” with Extended temp range

P

  Same as “7” with Extended temp range

Q

  Same as “D” with Extended temp range

R

  Same as “E” with Extended temp range

W

 ABZ, 10-24VDC Line Driver for cable runs 

up to 500 ft/120m using the Dynapar 
cable assemblies listed below 

Mating  Connectors (no cable)

MCN-N4

 

6 pin, style MS3106A-14S-6S

MCN-N5

 

7 pin, style MS3106A-16S-1S

MCN-N6

 

10 pin, style MS3106A-18-1S

607545-0001

 

10 pin bayonet, style MS3116-F12-10S

PS  

LED Output

Blank 

 No Option

01 

 Reverse Phasing 

(A leads B, CCW)

Available when Code 
5 is 0-2, 6 and 7 and 
when Code 6 is 0-2 
or 5-7

Summary of Contents for SERIES HS35R

Page 1: ...m mended for all encoder installations The shield should be connected to signal ground at the receiving device only Grounding For applications with high ground potential differ ences DO NOT ground the...

Page 2: ...S Disconnect power from equipment and encoder cable Ensure that you have the proper tools Typical tools that may be needed depending on the options chosen are 2 Phillips Screwdriver 5 32 Hex Wrench US...

Page 3: ...ROM MOUNTING FACE FOR USE OF END CAP 2 60 66 TYPICAL CLEARANCES FROM MOUNTING FACE RECOMMENDED 1 60 OR LONGER MATING SHAFT ENGAGEMENT MINIMUM 1 25 REQUIRED CHECK WOBBLE ON THIS FACE Follow the 3 step...

Page 4: ...ble 2 MS type mating connectors and prebuilt cables are rated NEMA 12 M12 Cable assemblies are rated IP67 3 For watertight applications use NEMA4 10 pin cable connector 109209 XXXX Only with cable opt...

Page 5: ...8 PIN M12 CABLES 75 19 05 67 17 07 75 19 05 85 21 59 89 22 61 40 2 50 63 50 2 02 51 35 3 02 76 80 54 13 7 4 43 112 5 2 36 59 9 11 2 8 1 95 49 5 06 1 52 2 25 57 2 3 80 96 5 3 X 120 2 53 64 3 2 50 63 5...

Page 6: ...001 Tether Kit 530 13 46 3 500 88 9 2 506 63 65 53 13 46 2 94 74 68 82 20 83 1 25 31 75 24X ON 3 000 76 2 B C D 20 51 24X 15 2 350 59 7 90 0 DIMENSIONS inch mm 530 13 46 3 500 88 9 2 510 63 75 3 525 8...

Page 7: ...rks with all electrical output configurations SPECIFICATIONS Note The following LED option specifications may supercede standard encoder specifications LED Characteristics On when output signal is 2 V...

Page 8: ...pin M12 J 8 pin M12 Ordering Information Code 2 PPR Code 7 Options Code 1 Model HS35R Heavy Duty Hollowshaft Encoder Code 3 Bore Size Code 6 Termination Code 4 Fixing Code 5 Output Format 0001 0003 00...