During operation these values may vary because of the prevailing
operating conditions.
2.1.1 Noise data
L
pA
= 94 dB(A), determined acc. to ISO 11201 and EN 500.
WARNING!
Loss of hearing caused by too high noise bur-
dens!
–
Wear your personal protective equipment (ear
protection).
L
WA
= 108 dB(A), determined acc. to ISO 3744 and EN 500.
2.1.2 Vibration data
Vector total of the weighted effective acceleration in three orthog-
onal directions:
Total vibration value a
hv
= 4.3 m/s
2
on crushed rock determined
acc. to ISO 5349 and EN 500.
Associated uncertainty K
= 0.7 m/s
2
, determined acc. to EN
12096.
Observe the daily vibration load (work safety acc. to 2002/44/EC).
Sound pressure level at the opera-
tor's stand
Guaranteed sound power level
Hand-arm vibration
Technical data – Noise and vibration data
DRP25D
14
Summary of Contents for DRP25D
Page 2: ...2...
Page 6: ...Table of contents DRP25D 6...
Page 7: ...1 Introduction Introduction DRP25D 7...
Page 11: ...2 Technical data Technical data DRP25D 11...
Page 15: ...3 Concerning your safety Concerning your safety DRP25D 15...
Page 37: ...4 Indicators and control elements Indicators and control elements DRP25D 37...
Page 39: ...5 Checks prior to start up Checks prior to start up DRP25D 39...
Page 45: ...6 Operation Operation DRP25D 45...
Page 52: ...Operation Parking the machine in secured condition DRP25D 52...
Page 53: ...7 Loading transporting the machine Loading transporting the machine DRP25D 53...
Page 58: ...Loading transporting the machine Transport wheels DRP25D 58...
Page 59: ...8 Maintenance Maintenance DRP25D 59...
Page 90: ...Maintenance As required DRP25D 90...
Page 91: ...9 Troubleshooting Troubleshooting DRP25D 91...
Page 96: ...Troubleshooting Malfunctions during operation DRP25D 96...
Page 97: ...10 Disposal Disposal DRP25D 97...
Page 99: ......
Page 100: ......