11
CS 141 M141EN4
Dismantle the clogged nozzle by hand. Blow the nozzle
(2) and fine filter (4) clean with compressed air, or
install replacement parts, and clean the clogged parts
at a later opportunity.
Wear protective goggles when working
with compressed air.
Sprinkler system
– Checking / Cleaning
Fig. 8 Sprinkler ramp
1. Water nozzles
Start the sprinkler system and make sure that no
nozzle (1) is clogged. If necessary, clean clogged
nozzles and the coarse filter located adjacent to the
water pump (2), see figures below.
1
EVERY 10 HOURS OF OPERATION (Daily)
Inspect the intake water filters of the pumps every day.
The water filter housing (2) can be removed.
Flush the housing and the filter clean with water and
then put them back into place.
Use only clean water in the water tank.
The water system must completely drained if
the roller is to be left unused for a longer
period or if temperatures below zero can be
expected. Remove the bottom plug to drain the
tank.
There are two strainers located behind the fuel tank.
Fig. 10 Water system (basic setting)
1. Water pump
2. Water strainer housing
2
1
1
2
4
3
2
1
Fig. 9 Nozzle
1. Sleeve
2. Nozzle
3. Compaction
4. Strainer
WARNING
CAUTION
CAUTION
Summary of Contents for CS 141
Page 2: ...19 ILF015WO1...
Page 29: ...27 CS 141 M141EN4...