29
CA 251 M251-1EN1
SPECIAL INSTRUCTIONS
The temperature limits apply to standard versions of
the roller.
Rollers that are fitted with additional equipment, such
as noise suppression, etc, may require extra observa-
tion in the higher temperature ranges.
A water jet should not be aimed directly at the
cap of the fuel tank or hydraulic reservoir. This
is especially important when using a high-
pressure jet.
Put a plastic bag over the filler cap of the fuel tank and
secure with a rubber band. This will prevent water from
entering the venting hole in the filler cap. This could
otherwise cause operational disturbance, eg, clogged
filter. Do not spray water directly on electric
components or the instrument panel.
In the event of fire in the machine, use an ABE-powder
fire extinguisher if possible. A BE type carbon dioxide
fire extinguisher may also be used.
If the roller is equipped with a protective structure, ie,
Roll Over Protective Structure, (ROPS), it must on no
account be subjected to welding and holes must never
be drilled in the structure. Never attempt to repair a
damaged structure, it must be replaced with a new one.
When using an auxiliary battery to assist starting,
always connect the positive terminal of the auxiliary
battery to the positive terminal of the roller battery, and
negative to negative.
Starting aid
Protective structure (ROPS)
Fire fighting
High-pressure washing
Temperature
Higher ambient temperature
max. +50°C (122°F)
Standard oils and other
recommended fluids
On leaving the factory the various systems and
components are filled with oil or fluid as indicated on
page 3. These can be used in temperatures from -10
°C to + 40 °C (14°F to (104°F)). The following
recommendations apply for operation in higher ambient
temperatures up to a maximum of +50°C (122°F):
The diesel engine can be run at this temperature using
the normal oil but for other components the following
fluids shall be used:
Hydraulic system: Shell Tellus Oil T100, or equivalent.
Other components using transmission oil: Shell Spirax
HD 85W/140, or equivalent.
Summary of Contents for CA 251