INSTRUCTIONS MANUAL – BA41E
File: 4700369943_ENG_NO.doc
Page 7 / 25
TECHNICAL DATA
BA41E
P/N 369231
3-phased current ( V/Hz )
400V-3-50Hz
Intensity at 50Hz ( A )
9.5
Speed at 50Hz ( rpm )
2850
Output at 50Hz kW-( hp)
4 (5.4)
Maximum vacuum ( % )
80
Suction capacity at 80 % vacuum
air m³/mn-( cu.ft )
0.5 - (17
11/16
)
Noise level measured in air connected to one
BB15 suction mat, at 1m from the machine
dB(A), according to ISO 6081.
Weight Kg-( Lb )
125 – (276)
Length x Width x Height mm
( in )
1300x710x860
(51x28x33.8)
IMPORTANT
The above information is a general description only, is not guaranteed and contains no warranties of
any kind
OPERATING INSTRUCTIONS
ELECTRICAL
CONNECTIONS
The electrical motor is connected for 400V-3-50Hz.
BEFORE
STARTING
Make sure that the tanks and the filter are cleaned.
Make sure that the main supply voltage coincides with electric motor voltage 400V-3-50Hz.
Fill both compartments of the tank with clean water. Fit the tank cover in place and secure.
Put in place the suction mat and connect the flexible hoses.
Make sure that flexible hoses and connections are undamaged.
If not used the second suction connection must be plugged (fig 5) .
STARTING
Start the motor and check direction of rotation . The arrow on the fan cover indicates the correct direction of
rotation (fig 4) . If it rotates in the wrong direction switch the electric motor off and then start again in the
reverse position of the switch.