Router
DTE
ISO2593Femal interface
M34 Female
interface
Standard V.35 Name
ISO2593 Male interface
M34 male interface
A
PGND
A
P
TD(A)
P
R
RD(A)
R
C
RTS
C
D
CTS
D
E
DSR
E
B
GND
B
F
DCD
F
S
TD(B)
S
Y
TCP(A)
Y
W
SCTE(B)
W
V
RCP(A)
V
H
DTR
H
T
RD(B)
T
AA
TCP(B)
AA
U
SCTE(A)
U
X
RCP(B)
X
7. Appendix
Explanation of CBL-V35-M34F/M34M-D cable
This cable is used to extend v.35 cable.
Converter
DCE
CBL-V35-M34F/M34M-D Customer DTE Cable
This cable is for the clients who have the need of extending cable. Please specify the
length of cable when ordering.
The making method is as follow:
The other pins are not connected.
Requirement: the material of cable is equal to or better than 80
°C
30V
Explanation of CBL-V35-M34M/M34M-X-D
This cable is cross end connection cable for the V.35 (DCE) interface connection of the
Converter and DDN type Node equipment. When using this cable, if the Node provides
the clock resource, the Converter must be set to the V.35 terminal clock mode. If the
Converter provides the clock source, the Node should follow the clock timing of the
24