background image

l

It is the responsibility of the OEM and installer to make sure that the maximum driving speed
of the wheelchair is limited as appropriate when the wheelchair is in a mechanically unstable
position, for example when the seat is raised.

l

It is the responsibility of the therapist/ installer to minimize any risk of use error, including
those arising from ergonomic features and/or the environment in which the device is intended
to be used.

l

The wheelchair set up and configuration process should take into consideration the

o

technical knowledge, experience and education, and

o

medical and physical condition, including the level of disability and capability, of each
individual user.

l

Prior to handing over the vehicle, make sure that users are fully able to operate the product by
giving them appropriate training on functionality and safety features, and having them test-
drive the vehicle in a safe area in the presence of their agent.

5.5 Electromagnetic compatibility (EMC)

Dynamic Controls' Electronic Controllers have been tested on typical, representative vehicles to
confirm compliance with the following appropriate EMC standards:

USA

: ANSI/RESNA WC-2:2009 Sec 21

Europe

: EN12184:2009 Sec 9.1

National and international directives require confirmation of compliance on particular vehicles. Since
EMC is dependent on a particular installation, each variation must be tested. The guidelines in this
section are written to assist with meeting EMC requirements in general.

Minimising emissions

To minimise emissions and to maximise the immunity to radiated fields and ESD, follow the general
wiring recommendations in section 2.1.1 of the DX System Manual.

5.6 Environmental statement

Dynamic Controls confirms that the product variants specified in this manual, as sub-assemblies of
electronic and electrical equipment supplied for further integration by a medical device manufacturer,
conform to applicable requirements of Directive 2011/65/EU, recast of Directive 2002/95/EC -
Restriction of the use of certain Hazardous Substances in electrical and electronic equipment.

This product has been supplied from an environmentally aware manufacturer.

Please be environmentally responsible and recycle this product at the end of its
life through your local recycling facility.

This product may contain substances that could be harmful to the environment if
disposed of into a landfill.

Do not dispose of this product in fire.

See also:

http://www.dynamiccontrols.com/designers-and-manufacturers/compliance

GBK59690 DX Heavy Duty Switch Joystick

Installation Manual Issue 5

Appendices - Page 13

Summary of Contents for DX-RJM-HD

Page 1: ...DX RJM HD Heavy Duty Switch Joystick DX RJM HD Installation Manual GBK59690 Issue 5 July 2015...

Page 2: ...Page left blank intentionally...

Page 3: ...d programming tool available only to authorised personnel The term accessory used in this manual refers to equipment that is ancillary to the main functioning of the DX System It does not refer to an...

Page 4: ...its licensors own and will retain all copyright trade secret and other proprietary rights in and to the documentation All materials contained within this manual in hard copy or electronic format are p...

Page 5: ...2 Connect 8 4 3 Program 9 4 4 Test 9 5 Appendices 11 5 1 Intended use and regulatory statement 11 5 2 Maintenance 11 5 3 Warranty 12 5 4 Safety and misuse warnings 12 5 5 Electromagnetic compatibilit...

Page 6: ...GBK59690 DX Heavy Duty Switch Joystick Installation Manual Issue 5 Page 4 Page left blank intentionally...

Page 7: ...DX System Manual will be referred to as DSM throughout the rest of this manual Note The DX RJM HD is part of the DX System Read the DX System Manual DSM before reading this manual The DX RJM HD has e...

Page 8: ...GBK59690 DX Heavy Duty Switch Joystick Installation Manual Issue 5 Page 6 Page left blank intentionally...

Page 9: ...securely to the wheelchair in a position that is convenient to the wheelchair user The selected position and orientation must give maximum mechanical and environmental protection to the DX RJM HD Avo...

Page 10: ...DX Master Remote Figure 3 Connecting to the DX System 1 Make sure that the DX System is off 2 Connect the DX RJM HD with a DX BUS cable to a DX Module This will usually be either the DX Power Module o...

Page 11: ...t Switch on the wheelchair with the ON OFF button on the Master Remote If the DX RJM HD is installed correctly its Status LED see Figure 4 will light up If the Status LED flashes the module is faulty...

Page 12: ...GBK59690 DX Heavy Duty Switch Joystick Installation Manual Issue 5 Page 10 Page left blank intentionally...

Page 13: ...EC and 21 CFR 820 30 The DX RJM HD has been designed such that the combination of the wheelchair and the DX System along with accessories as applicable complies with the Essential Requirements of the...

Page 14: ...he intended use and the recommendations of the wheelchair manufacturer 5 4 Safety and misuse warnings The DX RJM HD is a module of the DX System and therefore all safety and misuse warnings that appea...

Page 15: ...Sec 9 1 National and international directives require confirmation of compliance on particular vehicles Since EMC is dependent on a particular installation each variation must be tested The guidelines...

Page 16: ...GBK59690 DX Heavy Duty Switch Joystick Installation Manual Issue 5 Page 14 Page left blank intentionally...

Page 17: ...GBK59690 DX Heavy Duty Switch Joystick Installation Manual Issue 5 Page 15 Page left blank intentionally...

Page 18: ...0657 Fax 1 440 979 1028 usasales dynamiccontrols com Dynamic Controls is the world s leading manufacturer of electronic controls for power wheelchairs and scooters Dynamic Controls was established in...

Reviews: