24
to the desired number with the up arrow (↑) or down
arrow (↓).
A list of all parameter numbers is included in Table 3-3
and 3-4 to serve as a quick reference during operation.
Parameters that can only be displayed are numbered 01
through 25. The remaining parameters can be modified
from the keypad. Parameters that can be downloaded
through a serial interface are numbered 30 through 43.
Some parameters have built in limits. Refer to Table 3-2
for the parameter numbers have limits set.
Parameter Limits
Table 3-2
Parameter
Number
Parameter Description
Limits
Units
26
Maximum Speed
Speed of press SPM
30*
Angle No. 1
0 - 359.9
Degrees
31*
Speed No. 1
Speed of press SPM
32*
Angle No. 2
0 - 359.9
Degrees
33*
Speed No. 2
Speed of press SPM
34*
Angle No. 3
0 - 359.9
Degrees
35*
Speed No. 3
Speed of press SPM
36*
Angle No. 4
0 - 359.9
Degrees
37*
Speed No. 4
Speed of press SPM
38*
Angle No. 5
0 - 359.9
Degrees
39*
Speed No. 5
Speed of press SPM
40*
Angle No. 6
0 - 359.9
Degrees
41*
Speed No. 6
Speed of press SPM
42*
Creep Angle
Degrees
43*
Stop Angle
5
Degrees
44
Creep Speed
5
SPM
45
Micro Inch Speed
25% of max.
SPM
46
Inch Speed
50% of max.
SPM
47
Inch Accel Rate
1 - 100
SPM/Sec.
48
Initial Value of Linear Accel Ramp 0 - 3
SPM
49
Initial Accel Rate
1 - 100
SPM/Sec.
50
Operating Accel Rate No. 1
1 - 100
SPM/Sec.
51
Operating Accel Rate No. 2
1 - 100
SPM/Sec.
52
Operating Accel Rate No. 3
1 - 100
SPM/Sec.
53
Accel Rate Delta SPM No. 1
1 - 5
SPM
54
Accel Rate Delta SPM No. 2
1 - 5
SPM
55
Operating Decel Rate No. 1
1 - 100
SPM/Sec.
56
Operating Decel Rate No. 2
1 - 100
SPM/Sec.
57
Operating Decel Rate No. 3
1 - 100
SPM/Sec.
58
Decel Rate Delta SPM No. 1
1 - 5
SPM
59
Decel Rate Delta SPM No. 2
1 - 5
SPM
70
Wrong Direction Limit
0 - 10
Degrees
NOTE: *These parameters can be downloaded through a serial interface.