Starting up
58
APS09_013_0404GB
If the battery voltage is insufficient, the motor can be started using
the manual starting device.
"
Activate the choke lever.
Danger
Never direct the water jet at persons or animals − the high operating
pressure can lead to serious injuries.
The activated high−pressure gun produces recoil and torque.
Ensure equipment is secure and stable.
"
Open the high−pressure gun.
Caution
The pressure side must be fully open when the drive motor is
started, i.e. press the spray gun trigger.
This optimises the quick−fill feature on the pump and avoids dry runs.
The oil pressure that builds up during the manual starting phase will
be insufficient. The supply line must be disconnect from the
oil−pr essure sensor first.
"
Remove the supply line from the oil−pressure sensor.
"
Start the motor by pulling the cord on the manual starting
device.
Caution
Fuel solenoid valve remains activated in position 1 for a maximum of
30 seconds.
"
Once the motor is started, reconnect the supply line to the
oil−pr essure sensor immediately.
"
Deactivate the choke lever after a brief warming−up period.
Commissioning and operation then continue as with a normal start.
5.6
Starting the motor
using the manual