5. Jumper settings on the PCB
(Standard configuration =
printed in bold style
);
X = jumper insalled)
Jumper
position
position
function
a
b
J1
X
-
The input sensitivity is 2 mV
J1
-
X
The input sensitivity is 5 mV
J1
-
-
The input sensitivity is 8.5 mV
J2
X
-
The output level of the module is 0 dB
J2
-
-
The output level of the module is +6 dB
J3
X
-
The input sensitivity is 155 mV
J3
-
X
The input sensitivity is 775 mV
J4
X
-
Phantom power is switched off
J4
-
X
Phantom power is switched on
J5
X
-
The output signal of the coupled module is not affected
by
the damping circuit
J5
-
X
The output signal of the coupled module is affected by the
damping circuit
J6*
X
-
The internal power-on delay is effective
J6*
-
X
The module can be remote-controlled via the release input.
* Jumper 6 is no plugged jumper but a soldering bridge on the soldering side of the PCB. The pad in the centre and
on the right side is connected by a thin printed conductor, as seen from the soldering side. If the release input of the
module is not used, this conductor must be cut and the centre and the left side pad must be connected by a soldering
bridge.