background image

6. Slide the RCM-810 module into the slot and secure it

in place using the 2 screws

7. Gently push the 60 mm ribbon cable into the

connector labelled CN4 on the RCM-810 and the
connector labelled CN3 on the amplifier main board
(see illustration below)

8. Refit the top cover
9. Set the module’s CAN address using the ADDRESS

selector switches

10. Connect the interfaces required (CAN, Control Port)
11. Reconnect the mains lead and switch the amplifier

on, the RCM-810 is automatically detected and is now
ready for use

Installation (multi-channel amplifier)

Danger!
These installation instructions are for use by
qualified service personnel only. To reduce the
risk of electric shock do not perform any serv-
icing other than that contained in the owner’s
manual unless you are qualified to do so.

1. Switch off the power to the amplifier and disconnect

the mains lead

2. Remove the 8 screws (1) from the bottom cover of

the amplifier

1

2

3. Loosen the bottom cover as shown (2) and remove it

by pulling it out towards the front panel

4. Remove the cover panel from the rear panel (2

screws)

5. Release the 16-pole ribbon cable by cutting the tie

wrap (3)

6. Insert the RCM-810 module into the slot
7. Plug the 16-pole ribbon cable into the connector

labelled CN3 on the RCM-810 module

8. Slide the module into place locating it into the guide

slot (4) on side of the chassis and secure it in place
using the 2 screws

9. Refit the bottom cover making sure the ribbon cable

will not be damaged

10. Set the module’s CAN address using the ADDRESS

selector switches

11. Connect the interfaces required (CAN, Control Port)
12. Reconnect the mains lead and switch the amplifier

on, the RCM-810 is automatically detected and is now
ready for use

Ordering information

RCM-810

RCM-810 Remote Control Module for IRIS-Net

Order number 

F.01U.101.277

 

4 | RCM-810