6. Slide the RCM-810 module into the slot and secure it
in place using the 2 screws
7. Gently push the 60 mm ribbon cable into the
connector labelled CN4 on the RCM-810 and the
connector labelled CN3 on the amplifier main board
(see illustration below)
8. Refit the top cover
9. Set the module’s CAN address using the ADDRESS
selector switches
10. Connect the interfaces required (CAN, Control Port)
11. Reconnect the mains lead and switch the amplifier
on, the RCM-810 is automatically detected and is now
ready for use
Installation (multi-channel amplifier)
Danger!
These installation instructions are for use by
qualified service personnel only. To reduce the
risk of electric shock do not perform any serv-
icing other than that contained in the owner’s
manual unless you are qualified to do so.
1. Switch off the power to the amplifier and disconnect
the mains lead
2. Remove the 8 screws (1) from the bottom cover of
the amplifier
1
2
3. Loosen the bottom cover as shown (2) and remove it
by pulling it out towards the front panel
4. Remove the cover panel from the rear panel (2
screws)
5. Release the 16-pole ribbon cable by cutting the tie
wrap (3)
6. Insert the RCM-810 module into the slot
7. Plug the 16-pole ribbon cable into the connector
labelled CN3 on the RCM-810 module
8. Slide the module into place locating it into the guide
slot (4) on side of the chassis and secure it in place
using the 2 screws
9. Refit the bottom cover making sure the ribbon cable
will not be damaged
10. Set the module’s CAN address using the ADDRESS
selector switches
11. Connect the interfaces required (CAN, Control Port)
12. Reconnect the mains lead and switch the amplifier
on, the RCM-810 is automatically detected and is now
ready for use
Ordering information
RCM-810
RCM-810 Remote Control Module for IRIS-Net
Order number
F.01U.101.277
4 | RCM-810