ROUTINE MAINTENANCE FOR THE IMMERSION SEPARATOR
•
This unit must be filled at all times with either mineral oil or any other neutralizing liquid
required for
the precipitation of the dust being recovered.
•
This unit must be filled up to the green liquid level indicator line shown on the immersion separator.
•
Do not exceed the below recommended maximum dust recovery capacity.
Max. dust recovery capacity
Volume of liquid required
22 lbs / 10 kg
7.9 gallons / 30 liters
We recommend proceeding with the following maintenance after each use and after a maximum of 8
hours of consecutive use (see section for maintenance and clean-up procedure):
•
Before any maintenance shut the vacuum cleaner system off
•
Drain the liquid by opening the manifold drain valve
•
Discard all recovered material from inside of the immersion separator
•
Thoroughly clean all parts of the unit, including the suction hoses
•
Once unit is clean reinstall the parts inside the immersion separator and fill it with clean neutralizing
liquid before use
COALESCING FILTER ELEMENTS (CFE)
A Coalescing Filter Element (CFE) is assembled in the vacuum cleaner system at the exhaust port. Verify
if the CFE needs to be replaced as part of routine maintenance.
PLEASE CONSULT THE INSTRUCTION MANUAL AT ALL TIMES