16
Dymax BlueWave® LED VisiCure® User Guide
Fan Filter
The external fan filter should be inspected and cleaned periodically to prevent dust buildup from affecting
airflow through the unit. Spare filters are provided with each unit. The fan filters are washable and may
be reused. Remove the fan filter by removing the snap-on cover from the rear of the fan.
Figure 10. Cooling Fan Filter & Cover
Fuse Replacement
The unit is supplied with two Fuses that are installed in the Power Receptacle. To remove the Fuses,
unplug the unit and remove the Fuse Holder with a small screwdriver. Remove the Fuses from the Fuse
Holder and install new Fuses. Replace the Fuses with 2.0 Amp fast-blow types (Dymax
PN 37236
or
equivalent). Reinstall the Fuse Holder into the Power Receptacle.
Figure 11. Power Receptacle
Figure 12. Fuse Holder
Figure 13. Fuses (PN
37236)