GSM SECURITY ALARM SYSTEM GSM SECURITY ALARM SYSTEM
23 24
SOS
Sometimes you need to make an emergency call (e.g.: 110) for help,
such as when the old or children struck by a sudden illness, a fire occurs,
robbers intrude into your home. In such cases, you just need to press the [
]
key on the main device, or the [
] key on the remote controller. The
System will give an alarm at once, and make emergency calls automatically.
Operation by the remote controller: press the [
] key once.
Operation by the main device: press the [
] key.
■
Add a wireless siren into system
This is an optional configuration . To add a wireless siren into this alarm
system needs a built -in RF remitting module ,which is not a standard
configuration . Please consult your sales representative or distributors for
detailed information.
①
Enable the wireless control for wireless siren(The Host can not control
the wireless siren until enable the function):
In the status of programming, input the address code[41] on the Host, plus
[1/0]and then press [#] to confirm, there will be beep from the host when
the setting is completed.
Just make it as
:
【
program password
】
+
【
41
】
+
【
0 or 1
】
+
【
#
】
[0] means disable the function of connecting with wireless siren
[1] means enable the function of connecting with wireless siren
②
Wireless Code encryption:
there may be disturb signal from the other devices, so it will be better to
encrypt the wireless code
How to encrypt the code: in setup state,input 43+(2 difital n#
③
The method of matching:
a) Press the set key of wireless siren to make the sire in the status of
matching the code. Then it will wait for the signal from the host.(Please
take the manual for reference because different sires set up differently).
b) Press the"1234#"of the host, the "signal" of light will shine 5 seconds,
it will send the matching code signal to the wireless siren. After receiving
the signal, the sire will make a sound of “Di”,After the successful matching
of the wireless siren, when the host alarm, the sire will beep.
Maintenance
System Inspection
To make sure that the System runs steadily, reliably and safely, regular
maintenance and detection are a must. A full inspection to the main device
should be conducted every 3 months; and we suggest that the detector get
an inspection monthly or every 3 month at least.
Inspecting the main device:
1.
Check whether it can arm or disarm normally.
2.
Check whether it can make calls when alarming.
3.
Check whether it can receive signals from detectors and whether the
backup battery is normal.
Inspecting the detectors:
1.
Check whether the detectors can give a normal alarm by manually
triggering them.
2.
Check whether all detectors to prevent low battery.
3.
Check whether all wireless detectors can communicate with the
main device by testing the transmission condition.