FS20W
14
4
)
no reaction when turn on for brush or suction motor
troubleshooting method: after the switch is turned on, if the corresponding indicator light is
on the panel.
If the indicator light is on, check whether the fuse - > relay - > - related cable is loose or
damaged;
If the indicator light is not bright, it may be the main control circuit board due to water
damage;
5
)
suction motor can not be closed, even the key is closed, suction motor still running.
Rule out method: observe the panel indicator, if close the water absorption switch, water
indicator light off, the suction motor is still rotating, it is possible that the relay of suction
motor is damaged. If close water absorption switch, water indicator light still on, it is
possible that the main control circuit board damage.
6
)
water absorption effect is not good.
methods: to observe the state of suction of squeegee, and choose different methods to
adjust the squeegee.
(1) in the smooth floor, still water left after suction, inspect if the rubber blade and floor are
uniform contact.
rear rubber blade and the floor
keep 90 degree, to keep one
side of rubber blade and floor
contact, when this side wear
and tear, we could change the
other side, so that the rubber
blade could be used repeatedly
four times, save cost.
this status of rear rubber blade can
not get good result, but also damage
the rubber blade easily, once this side
of rubber blade damage, the other
side can not be reused, greatly
shorten the service life of the rubber
blade.
floor
right
wrong
the rubber blade of this machine is double side four to use, can effectively reduce your
using cost, so that you can achieve the value of maximum.
select rubber blade or need oil resistant, please contact local dealer.