background image

 

D3000

 

Series

 

 

User

 

Manual

 

 

D3000

USER

EN/09F/v2

                                                                          ‐ 

9

 

                      

Test panel sound 

Press [

OK

] to start the test.  The display will read “Panel sounder ON” and the main 

sounder inside the building will be heard.  Press [

OK

] to end the test. 

View log 

Press [

OK

] to view the log.  You will then have 3 options as described below: 

 

View full log 

 

This option allows you to see all entries in the event log. 

 

View alarm log 

 

This option allows you to see the alarm entries in the event log. 

 

View user log 

 

This option allows you to see the entries in the event log relating to user activity. 

To view the selected log, press [

OK

].  You will then be asked to enter a start date (i.e. the 

date of the oldest event to be viewed); change this if required then press [

OK

]. 

You will then be asked to end an end date (i.e. the date of the newest event to be viewed); 
change this if required, then press [

OK

]. 

The display will now show each event and the date and time it occurred, starting with the 
most recent.  Pressing the [

flip

] key may display additional information for the displayed 

event.  Use the [

] and [

] keys to move up and down through the event log.  When you have 

finished, press the [

esc

] key. 

Change your own code 

To change your user code, press [

OK

].  The bottom line of the display will then show a string 

of “

*

”, showing that a code exists (

NOTE

: you are not able to see what the code is).  Enter 

your new user code followed by [

OK

] to overwrite the old code. 

Add / delete users 

Before entering this option, ensure that you have a record of all the users on the system.  To 
edit user details, press [

OK

] when this option is displayed. 

-  Use the [

] and [

] keys to display the user number to be edited.  Press [

OK

]. 

-  The user code for that user can then be entered (new user) or changed if required 

(existing user).  If the display shows a string of “

*

” characters, then a code already 

exists.  Press [

OK

] to leave the code unchanged, or enter the new user code 

followed by [

OK

].  To delete this user, press [

C

] to clear the code followed by [

OK

]. 

-  The user name can then be changed (if required).  Press [

OK

] to leave the user 

name unchanged, or enter a new name as required (user the [

] and [

] keys to move 

around the name, or clear the display with [

C

]).  Press [

OK

] to accept the user name.  

Refer to Appendix 1 for text entry using the keypad. 

-  User attributes can then be changed for this user (if required) as follows: to select or 

de-select the attribute, press the [

flip

] key.  A “

-

“ character on the display means that 

the relevant attribute is de-selected.  Press [

A

] will select all the attributes, whereas 

pressing [

C

] will clear all the attributes. 

Access control 

The first “

A

” on the display indicates that the user code has no access to setting or 

un-setting the system, or to the menus.  Entry of a user code with the access control 
attribute activates an output – this is usually used for door entry. 

Summary of Contents for D3000 Series

Page 1: ...t your Installer explains how the system works and the level of access each user has If you have any queries on the configuration or the operation of this Intruder Alarm System contact your Alarm Company on the following telephone number Alarm Company _____________________________________________ Telephone _____________________________________________ NOTE This manual covers 3 products D3001 D3021...

Page 2: ...Advanced operations 8 Set or unset groups 8 Omit 24Hr zones 8 Tests 8 Test bell 8 Test strobe 8 Walk test 8 Test RKP LEDs 8 Test RKP sound 8 Test panel sound 9 View log 9 View full log 9 View alarm log 9 View user log 9 Change own code 9 Add delete users 9 Access control 9 Smoke reset 10 Omit zones 10 Arm only 10 Reset system 10 Set date and time 11 Remote access 11 Intercom 11 Helpline 11 Allow e...

Page 3: ...USER EN 09F v2 3 The main parts of the keypad are used as follows Display This screen is continuously updated informing you of what is happening on the system Set indicators These red indicators are ON if the appropriate group s are set See Note on page 4 Ready indicators These green indicators are ON when the appropriate group s are ready to be set If the indicator is OFF when you want to set the...

Page 4: ...indicator will flash if the mains is off or if there is a problem with the internal battery When this indicator is flashing the display will show details of the problems Microphone Used for the Intercom and the Helpline features These features are only available if a D3201 or D3202 keypad is used Proximity reader This feature is useful if users find it difficult to remember codes when setting and ...

Page 5: ...s to the system the following information is required User number A two digit reference number used internally to identify which user is using the system User name A text name to identify each user User code The code that is used to confirm that the person at the keypad is an authorised user User functions These define whether an individual user has access to specific functions within the user s m...

Page 6: ... enter the building via the correct entry route to avoid setting off the alarm The intermittent tone indicates that the system is in entry mode Go straight to the keypad and enter your user code followed by the OK key or place the tag against the keypad to unset all of the system Alternatively enter your user code followed by a Quick Set key A B C or D to unset specific group s The red indicators ...

Page 7: ... about to change the group to unset or set Press OK to continue The display will now show the zone reference for the first zone that can be omitted Move up and down through all the omitable zones using the and keys pressing the 0 key to omit it or the 1 key to activate it Press OK to start the setting mode If a detector is active at this point the system will return to the unset condition Simply s...

Page 8: ... this option there are further options as defined below Press the and keys to move between these options then press OK to select the required test Pressing the and keys will cycle around the options i e pressing the key after the last option will then show the first option again Test bell Press OK to select The display will read Bell ON and the outside sirens or bells will begin Press OK to end th...

Page 9: ...E you are not able to see what the code is Enter your new user code followed by OK to overwrite the old code Add delete users Before entering this option ensure that you have a record of all the users on the system To edit user details press OK when this option is displayed Use the and keys to display the user number to be edited Press OK The user code for that user can then be entered new user or...

Page 10: ...e desired access The user can be given access to autogroups These are the groups which the user will set when entering their code followed by the OK key or by placing their tag against the keypad Any combination of groups within those allocated above can be selected The first screen shows the autogroups within groups 1 to 10 groups 1 to 4 on D3021 or D3022 To allocate autogroups to groups 11 to 20...

Page 11: ...remote location usually your Alarm Company Three options exist namely Call downloader Answer call and Start remote servicing You will be instructed by your Alarm Company when and how to use these options Intercom Press OK to contact another keypad on the system If there are more than 2 keypads you will be asked which one you want to contact Enter the keypad number and press OK NOTE when using the ...

Page 12: ...eys enter text Multiple presses of each of the keys enter text as defined below Press Displayed 1 1 2 a b c 2 A B C 3 d e f 3 D E F 4 g h i 4 G H I 5 j k l 5 J K L 6 m n o 6 M N O 7 p q r s 7 P Q R S 8 t u v 8 T U V 9 w x y z 9 W X Y Z 0 space 0 The cursor will automatically move right one second after the last key press Alternatively the cursor can be moved right manually with the key or left wit...

Page 13: ...d KP Sounder ON Test Panel Sound Panel Sounder ON View log View Full Alarm User Log Start Date End Date Change own code Change Own Code Add Delete users Select User Access Code Operator Name Attributes Operator Groups Groups 1 10 and 11 20 Autoset Groups Groups 1 10 and 11 20 Menu Access Set date and time dd mm yyyy hh mm Remote access Call Downloader Answer Call Start Remote Servicing Allow engin...

Page 14: ... each time an alarm is generated After an alarm the system must be reset before it can be set again also see customer reset Entry mode When the system is set opening the relevant door will start the entry mode You will then be given enough time to walk to the keypad and enter your user code to unset the system without generating an alarm It is very important however that you go straight to the key...

Page 15: ... When an alarm condition is generated it is common to trigger flashing lights outside the building These lights are referred to as strobes Unset When the system is unset the building is not protected and it is safe to walk around without triggering the alarm Walk test This feature provides the user with a facility to periodically test that all detectors on the system are working correctly D3000 Se...

Page 16: ...D3000 Series User Manual D3000 USER EN 09F v2 16 NOTES ...

Reviews: