Installation Manual for     

D1530 Series                         

EN Compliant Grade 3 Type A 

Power Supplies 

D1530 Series 

D1531 

Grade 3, 1A 

D1532 

Grade 3, 2A 

 

INSTALLATION 

Mount the metal enclose onto the wall in the usual manner. 

Connect the Live, Earth and Neutral terminals to the un-switched fused spur. 

Connect 0V, tamper and fault outputs to the control panel as appropriate (see control panel 
manual for details).  Connect 12v and 0v to the system. 

Fit the batteries and ensure that the tamper switch is connected to the PCB. 

Switch on the AC supply and confirm that the “EPS OK” LED is on. 

If not all the batteries are to be fitted, the “Status” LED will blink.  Press the “Learn” button, 
and the “Status” LED will flash quickly while the battery configuration is learned in. 

The “Status” LED will start to flash slowly indicating that the batteries are charging.  If the 
“APS OK” LED is off, the battery voltage may be low.  Wait for a couple of minutes to 
confirm that the “APS OK” LED comes on.  When the batteries are fully charged, the 
“Status” LED will go out. 

  

These products are suitable for use in systems designed to comply with 

PD6662: 2010 at Grade 3 and Environmental Class 2. 

 

Dycon Ltd 

 

Tel: +44 (0)1443 471 060 - Fax: +44 (0)1443 479 374 

Cwm Cynon Business Park – Mountain Ash – CF45 4ER - UK 

www.dyconsecurity.com

 -  

[email protected]

     

Summary of Contents for D1531

Page 1: ...e EPS OK LED is on If not all the batteries are to be fitted the Status LED will blink Press the Learn button and the Status LED will flash quickly while the battery configuration is learned in The Status LED will start to flash slowly indicating that the batteries are charging If the APS OK LED is off the battery voltage may be low Wait for a couple of minutes to confirm that the APS OK LED comes...

Page 2: ...AULT PSU FAULT Green LED goes out and relay contacts open if Green LED goes out and relay contacts open if Green LED goes out and AC power fault PSU over voltage fault Thermal shutdown Total power down Battery not connected Battery load test fault Battery voltage low Total power down Output voltage low Total power down All outputs open and LEDs out indicates a total power down Status LED Status LE...

Page 3: ...n after a complete power down Battery protection The batteries and electronic circuitry are protected against reverse polarity connected by a self resetting electronic fuse The batteries are also protected against deep discharge which will be invoked when the battery terminal voltage has dropped to 10 5v Battery monitoring The batteries are monitored for low voltage disconnection and load test Whe...

Page 4: ...e table below To meet the requirements of EN50131 1 the figures below must be divided by 2 2 e g 1 5A becomes 0 68A D1531 D1532 D1531 D1532 1 x 7 AH 0 5A 0 5A 1 x 8 AH 0 6A 0 6A 2 x 7 AH 1 0A 1 0A 2 x 8 AH 1 0A 1 2A 3 x 7 AH N A 1 5A 3 x 8 AH N A 1 8A 1 x 17 AH N A 1 3A 1 x 18 AH N A 1 4A 2 x 17 AH N A 2 0A 2 x 18 AH N A 2 0A Note in both the above tables it is assumed that the system transmits a ...

Reviews: