Installation Manual for
D1530 Series
EN Compliant Grade 3 Type A
Power Supplies
D1530 Series
D1531
Grade 3, 1A
D1532
Grade 3, 2A
INSTALLATION
Mount the metal enclose onto the wall in the usual manner.
Connect the Live, Earth and Neutral terminals to the un-switched fused spur.
Connect 0V, tamper and fault outputs to the control panel as appropriate (see control panel
manual for details). Connect 12v and 0v to the system.
Fit the batteries and ensure that the tamper switch is connected to the PCB.
Switch on the AC supply and confirm that the “EPS OK” LED is on.
If not all the batteries are to be fitted, the “Status” LED will blink. Press the “Learn” button,
and the “Status” LED will flash quickly while the battery configuration is learned in.
The “Status” LED will start to flash slowly indicating that the batteries are charging. If the
“APS OK” LED is off, the battery voltage may be low. Wait for a couple of minutes to
confirm that the “APS OK” LED comes on. When the batteries are fully charged, the
“Status” LED will go out.
These products are suitable for use in systems designed to comply with
PD6662: 2010 at Grade 3 and Environmental Class 2.