background image

- 2 -

INSTALL CLOSET BOLTS

Install closet bolts in flange channel
and slide into place parallel to wall.

TIP: 

Place 2 pieces of masking tape  

on floor (as shown) to help with  
alignment in step 4.

Apply weight evenly. Do not move
after placement. Water tight seal  
may break.

  

7302362-100 Rev. A (5/18)

1

4

2

5

3

!

WARNING: 

Overtightening of water supply

line nuts could result in breakage

and potential flooding. If the

connection leaks after hand

tightening, replace the supply

line. Do not use any type of

sealant on the water supply

connection.

Use of plumber’s putty,

pipe dope, or any other

type of sealant will void

the warranty.

For seat installation,

see instructions

included with seat.

*

!

CLOSET FLANGE

DRAIN

    CENTER LINE

CLOSET BOLTS

CLOSET BOLT

WASHER

NUT

Press 

firmly.

WAX RING

Summary of Contents for Equility D22690A109

Page 1: ...d flush tank completely Towel or sponge remaining water from tank and bowl b Disconnect and remove supply line NOTE If replacing valve first shut off main water supply c Remove old mounting hardware remove toilet and plug floor waste opening to prevent escaping sewer gases d Remove closet bolts from flange and clean away old wax putty etc from base area NOTE Mounting surface must be clean and leve...

Page 2: ... A 5 18 1 4 2 5 3 WARNING Overtightening of water supply line nuts could result in breakage and potential flooding If the connection leaks after hand tightening replace the supply line Do not use any type of sealant on the water supply connection Use of plumber s putty pipe dope or any other type of sealant will void the warranty For seat installation see instructions included with seat CLOSET FLA...

Page 3: ... CLEANING ADJUSTMENTS Adjust water level Water level should be adjusted to level indicated on tank by adjusting float cup See Step 7 for water level adjustment method If bowl fails to siphon an adjustment may be required with the lift chain Simply remove the bead chain from the retainment clip and take up slack on the chain and reinsert on lift rod Make sure the chain is not too taught Turn on wat...

Page 4: ...NED TO THE LOCKED POS For troubleshooting information please contact 2001 Fluidmaster Inc Registered trademark of Fluidmaster Inc 30800 Rancho Viejo Road San Juan Capistrano CA 92675 949 728 2000 800 631 2011 www fluidmaster com NOTE Pictures are representative and may not exactly depict the flush valve PARTS See list label under the tank cover TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE CORRECTI...