- 1 -
INSTALLATION INSTRUCTIONS
SA
VE FOR FUTURE USE
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2018
7302362-100 Rev. A (5/18)
RECOMMENDED TOOLS AND MATERIALS
Most of the procedures require the use of common tools and materials, which are available from hardware and plumbing
supply stores. It is tessential that the tools and materials be on hand before work is begun.
Thank you for selecting DXV. To ensure this product is installed properly, please read these instructions carefully before you begin.
(Certain installations may require professional help.) Also be sure your installation conforms to local codes.
CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!
NOTE: Pictures may not exactly define contour of china and components.
!
Equility
™
(Formerly LYNDON
®
)
1-Piece Toilet, Concealed Trapway
Right Height
®
, Elongated, HET
Models: D22690A109 - Left-Hand Trip Lever
D22690A108 - Right-Hand Trip Lever
Gasket
Wax Ring
Regular Screwdriver
10'
Level
Flexible Supply Tube
Closet Bolts
Putty Knife
Tape Measure
Hacksaw
Sealant
Adjustable Wrench
a.
Close toilet supply valve and flush tank completely. Towel or sponge remaining water from tank and bowl.
b.
Disconnect and remove supply line.
NOTE:
If replacing valve, first shut off main water supply!
c.
Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases.
d.
Remove closet bolts from flange and clean away old wax, putty, etc. from base area.
NOTE:
Mounting surface must be clean and level
before
new toilet is installed!
NOTE:
Distance from wall to
closet flange centerline must
be as listed below:
IMPORTANT:
Water supply on
the wall is required at 2-1/4" or 8"
from centerline of the toilet (see
rough-in). First suggested
position is hidden behind the
toilet. The geometry of the toilet
gives space for this installation.
The second suggested position is
next to the toilet. Between these
two positions, the space for the
supply between wall and toilet is
limited to 4-1/2". In this case,
check your supply and hose
dimensions.
1
2
REMOVE OLD TOILET
ALL INSTALLATION PROCEDURES MUST COMPLY IN STRICT ACCORDANCE WITH APPLICABLE LOCAL
PLUMBING AND BUILDING CODES
ROUGHING-IN DIMENSIONS:
30-3/16"
(767 mm)
7-1/2"
(191 mm)
7/8" (23 mm)
18-1/2"
(470 mm)
3-5/16"
(85 mm)
3-1/8"
(79 mm)
7-11/16"
(195 mm)
13-11/16"
(347 mm)
16-1/2"
(419 mm)
14"
(356 mm)
10-5/8"
(270 mm)
30-13/16"
(783 mm)
12"
(305 mm)
FINISHED
WALL
C/L OF SEAT POST
HOLES 5-1/2"
(140mm) CENTERS
14"
(356 mm)