- 4 -
M965555 Rev. 1.1
•
Loosen and remove LEVER HANDLE
(1).
Loosen HANDLE SCREW
(2)
with 2.5mm Hex Wrench and then pull HANDLE BASE
(3)
off.
•
Unscrew ESCUTCHEON CAP
(4)
. Unscrew theCARTRIDGE NUT
(5)
.
•
Remove CARTRIDGE
(6)
. Clean inlets of CARTRIDGE
(6)
and MANIFOLD
(7)
.
•
Reassemble CARTRIDGE
(6)
. Replace CARTRIDGE NUT
(5)
, CAP
(4)
and
HANDLE assembly, check flow.
•
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, first turn off water supply then:
•
If SPOUT (7) leaks at swivel point the O-RINGS (8) need to be replaced. To remove SPOUT (7)
:
•
Loosen the SPOUT SET SCREW
(9)
with a 3mm Hex wrench.
•
Rotate the SPOUT
(7)
side to side while pulling upward to remove SPOUT
(7)
from faucet body.
•
Replace the defective parts, grease O-RINGS
(8)
then push SPOUT
(7)
back into position. Tighten SET SCREW
(9)
.
•
Check that SPOUT
(7)
rotates freely and does not leak at the swivel point.
SERVICE
2
3
1
4
5
6
7
CLEAN
9
3mm HEX WRENCH
5
TEST INSTALLED FAUCET
•
Unthread SPRAY HOSE
(3)
from SPRAY
(2)
.
•
Turn on water supplies and check connections for leaks
.
•
Hold HOSE END
(3)
in sink and operate HANDLE
(1)
on and off,
hot and cold to flush water lines thoroughly. Replace SPRAY
(2)
.
•
Pull SPRAY
(2)
out and check hose and supply connections
for leaks. Check that SPRAY HOSE
(3)
and WEIGHT
(4)
slide
up and down freely and do not interfear with supplies or waste
outlet plumbing.
•
Check all drain connections for leaks.
•
Move HANDLE
(1)
to "off" position.
•
Move HANDLE
(1)
into "off" position.
3
4
HOT & COLD
SUPPLIES
4
8
1
2
3
REMOVE
INSTALL
7