background image

15

3 min

3 min

5-10

times

repeat

No skewed cut!

1

4

3

2

1

4

2

3

3/8”

3/8”

3/8”

1/2”

1/2”

1/2”

mount drain 
saddle here

never
mount
here

never mount
here

Note: For a pre- or post-filter you only need to connect its inlet and outlet. For the membrane 
you have to connect the third outlet – to the waste water line. This outlet is located off the 
center of the membrane housing. Elbow check valve fitting (with the arrow) has to be con-
nected to the central (permeate) outlet of the membrane housing.

close the cover, reconnect the external tubes and place the unit back in its place

3 min

3 min

5-10

times

repeat

No skewed cut!

1

4

3

2

1

4

2

3

3/8”

3/8”

3/8”

1/2”

1/2”

1/2”

mount drain 
saddle here

never
mount
here

never mount
here

After you finished changing filters or the membrane follow the “initial washing” procedure as 
described above. With initial operation, check for leaks. If a leak is observed, verify that the 
tube or branch pipe of the filter/membrane housing is pushed into the quick fitting far enough 
to seal the tube against the O-ring and that the tubing was cut at 90

o

.

membrane  K866

pre-filter  K871

pre-filter  K870

post-filter K880

waste water outlet

permeate (to tank)

R.O. unit inlet

to the faucet

R.O Filtration Unit Internal Connections Chart

Summary of Contents for Prio Expert MO600

Page 1: ...Prio Expert User s Guide MO600 Reverse Osmosis Filtration System with Pump Box Storage Tank Pump Box Unit with Auto Flush Main Filtration Unit Set ...

Page 2: ...ovetheplugfromtheelectricaloutletandshutofftheinletvalveduringyour vacations or other extended periods of time when the appliance is not in use Unplug the pump unit from the electrical outlet while servicing the main filtration unit and changing the membrane or filters Do not use the appliance if operating requirements such as water tempera ture water pressure electrical supply etc are not met The...

Page 3: ...he scale and debris build up on the membrane outer surface The booster pump increases pressure to radically improve the performance and effective ness of the R O unit in all three key areas increases filtered water flow production rate increases rejection rate improves water purification quality increases recovery rate de creases amount of waste water Prolongs the membrane and pre filter s service...

Page 4: ...h the faucet and waste water is drained through the drain saddle Detailed connection scheme is shown on the following charts Usually both units the pump box and the R O unit with tank are placed under the sink such as in your kitchen and the filtered water faucet is mounted on the sink deck near your normal water tap After installation you will get clean water by simply opening the filtered water ...

Page 5: ...nletwateroritspressureistoolow Thehighpressureswitch shuts off the pump when the filtered water faucet is turned off and water storage tank is full Pump The pump box unit is equipped with a low voltage booster pump powered by the included transformer for safe operation Inlet Valve An adapter ball valve is included to be installed into the cold water supply line to feed water to the pump box inlet ...

Page 6: ... 10 5 gpg Iron 0 1 mg L Manganese 0 05 mg L Hydrogen Sulfide 0 00 mg L Maximum supply water TDS 1000 ppm Indoor use only Electrical input AC 100 240V 50 60 Hz Maximum length of the line between the pump unit and the membrane split installa tion 50 ft 15 m purchase of extra tubing may be required Tubing Performance Performance of the appliance such as filtered water delivery rate rejection rate etc...

Page 7: ...Notes 1 Shut off the cold water supply under the sink or the location where the system will be installed If the existing valve is inoperable the water supply to the house must be shut off Then relieve the water pressure by opening the cold water tap Do not connect the system to hot water source 2 Depending on your plumbing system and sink countertop type you may need to use tools like variable spe...

Page 8: ...t valve waste water outlet permeate outlet to the tank union tee fitting from waste water outlet of the membrane to drain or waste water collection container check valve filtered water faucet from inlet valve to R O unit inlet from filtered water outlet of the R O unit General connection scheme ...

Page 9: ...o Connect the Tubing to a Fitting 1 Remove the lock if present not present in self locking fittings 2 Push Insert the tube firmly until full stop 3 Pull the collet back slightly 4 Replace the lock if present To Disconnect the Tubing 1 Remove the lock if present not present in self locking fittings 2 Push the collet and hold 3 Pull the tubing out 4 Replace the lock if present No skewed cut 1 4 3 2 ...

Page 10: ...t for details 2 Create hole for the filtered water faucet and install it mount drain saddle here never mount here Tip If you have a soap dispenser or a water sprayer in an existing hole you may remove it and use its hole for the filtered water faucet 3 Install drain saddle 3 8 3 8 1 2 1 2 mount drain saddle here never mount here never mount here The square foam gasket with a circle cut out must be...

Page 11: ...ng of the pump box unit Insert the supply tubing from the RO unit fitting of the pump box unit into the supply inlet of the R O filtration unit Connect with the tubing the tank outlet fitting of the R O filtration unit with the permeate fitting of the pump box unit through the T fitting on the way Then connect with the tubing the branch of the T fitting with the tank valve fitting Insert the waste...

Page 12: ...r flow appears from the faucet the flow is weak and inconsistent wait for 2 3 minutes more and shut off the faucet wait for auto flush to complete 18 s 3 min 3 min 5 10 times repeat saddle here never mount here never mount here repeat the cycle open the filtered water faucet wait for 3 minutes shut off the filtered water faucet wait for auto flush to complete 5 10 times after you finished with pre...

Page 13: ...cement of a component should be with one of identical specifications as defined by the manufacturer to assure the same efficiency and contaminant reduction performance To reduce the risk of water leakage or flooding and to ensure optimal R O system performance Change the disposable pre filters every 6 months or sooner if you observe a noticeable reduction in water production rate Change the dispos...

Page 14: ...ts place foreasieraccess disconnectexternaltubes if necessary and open the unit s cover locate the filter membrane to be changed disconnect its inlet and outlet fittings and remove it take new filter membrane and install it in the place of the removed one observing the water flow direction arrow on its label and restoring the connections see the internal con nections chart for details 3 min 3 min ...

Page 15: ...ernal tubes and place the unit back in its place After you finished changing filters or the membrane follow the initial washing procedure as described above With initial operation check for leaks If a leak is observed verify that the tube or branch pipe of the filter membrane housing is pushed into the quick fitting far enough to seal the tube against the O ring and that the tubing was cut at 90o ...

Page 16: ...tinue the following steps If the tank feels light that means it is not time yet to recharge the tank at this moment Locate the air valve Use bicycle tire air pump to pump air into the tank through this valve Keep the faucet open while pumping air so that all water inside the tank can be purged After all water has been drained from the tank use an air pressure gauge to check the tank pressure The t...

Reviews: