trk-101-P 

PTZ Tracker 

Installation Manual 

 

 

 

 

 

 

 

   

 
 
 
 
 

 

 

 

 

 

Rev 1 

 

February 2015 

 

The contents of this guide may 

not be reproduced or reprinted 

in whole or in part without the 

express written permission of 

DVTEL, INC. 

DVTEL INC. 

65 Challenger Road 

Ridgefield Park, NJ 07660 

 

The contents of this manual may not 

be reproduced or reprinted in whole 

or in part without the express written 

permission of DVTEL, INC. 

Summary of Contents for TRK-101-P

Page 1: ...not be reproduced or reprinted in whole or in part without the express written permission of DVTEL INC DVTEL INC 65 Challenger Road Ridgefield Park NJ 07660 The contents of this manual may not be rep...

Page 2: ......

Page 3: ...ty to Connect the Unit to the Network 8 3 2 4 Connecting the Video Source Camera to the Unit 11 3 2 5 Configuring PTZ Camera Settings on the Encoder 12 3 2 6 Connecting the Analog Video Output to an A...

Page 4: ...Nuts Removed 6 Figure 6 Inserting Units into Rack Mount Panel 6 Figure 7 DNA Discovery Window 9 Figure 8 DNA Assign IP Use DHCP Dialog Box 9 Figure 9 DNA Assign IP Static IP Dialog Box 10 Figure 10 Lo...

Page 5: ...ry or death Avertissement est un message pr ventif indiquant qu une proc dure ou condition pr sente un risque potentiel de blessure ou de mort A Caution is a precautionary message that indicates a pro...

Page 6: ...ignes de s curit les normes et les codes lectriques ainsi que la l gislation en vigueur sur le lieu d implantation des unit s Proprietary Rights and Non Disclosure This manual is delivered subject to...

Page 7: ...en place de mesures de s curit insuffisantes Le non respect de tout ou partie des proc dures recommand es ou des messages d AVERTISSEMENT ou d ATTENTION de la part de l installateur du propri taire o...

Page 8: ...et ne retirez pas ses vis Aucune pi ce se trouvant l int rieur de l unit ne n cessite un entretien par l utilisateur 4 Seul un technicien form et qualifi est autoris entretenir et r parer cet quipeme...

Page 9: ...ctor 5 If you use an extension cord with this system make sure that the total ampere rating on the products plugged into the extension cord does not exceed the extension cord ampere rating 6 To avoid...

Page 10: ...rallonge avec ce syst me assurez vous que l amp rage total des produits branch s sur la rallonge ne d passe pas l amp rage nominal de celle ci 6 Pour viter tout risque de choc lectrique ou d endommage...

Page 11: ...fety Cables and electrical cords should be routed in a manner that prevents safety hazards such as from tripping wire fraying overheating etc Ensure that nothing rests on the unit s cables or power co...

Page 12: ......

Page 13: ...matic notification You can define the events and location in the video of the image that can be detected with user customizable rules and positioning criteria Figure 1 trk 101 P Unit In addition to it...

Page 14: ...el The power connection panel of the unit includes the following connections Item Description Grounding Terminal For connecting the unit to the protective ground earth according to local regulations a...

Page 15: ...e in the second phase of the boot Requires resetting the unit Steady yellow Reset button was pressed for 5 15 seconds and entered Technician mode Requires resetting the unit Flashing yellow 500ms inte...

Page 16: ...udes detection overlays and additional On Screen Display OSD information Typically connected to analog video equipment such as analog video displays or analog video recording device or digital video r...

Page 17: ...e air is free to circulate around the unit The unit is protected from direct weather conditions for example sunlight rain dust and so on Caution To avoid damage from overheating or unit failure assure...

Page 18: ...ount panel by inserting it through the holes as shown in Figure 6 Figure 6 Inserting Units into Rack Mount Panel 3 Fasten each unit using the nuts and washers removed in step 1 making sure to first pl...

Page 19: ...Figure 3 trk 101 P Power Connection Panel 2 Attach a properly rated ground cable Make sure the ring spade terminal of the grounding cable is between the toothed washers Tighten the screw 3 Ensure that...

Page 20: ...tic IP address rather than with DHCP This ensures that the IP address will not automatically change in the future and interfere with configurations and communication DNA has a simple user interface an...

Page 21: ...file by clicking the icon The DNA application opens and the device is displayed in the window 3 Select the unit by right clicking on it Figure 7 DNA Discovery Window 4 If there are devices located on...

Page 22: ...ox iii In the IP Address Gateway and Mask enter the respective LAN VLAN optional DNS values Figure 9 DNA Assign IP Static IP Dialog Box iv Click Update and wait for OK status to be displayed 7 Repeat...

Page 23: ...e unit See Figure 4 trk 101 P Video Connection Panel page 4 To set the unit s video standard via its web interface 1 Enter the IP address of the unit in a browser The unit s Login window opens 2 Login...

Page 24: ...ice ID Baud rate Parity Start bits Stop bits 6 Click Start PTZ Setup to run the wizard to configure PTZ settings For more information see section 5 3 1 2 1 1 in the HTML Edition Units User s Guide 7 W...

Page 25: ...fore performing the following procedure Avertissement D branchez l alimentation de l unit avant d effectuer la proc dure suivante 1 Connect the leads from the external device dry contact output using...

Page 26: ...LY OPEN or NORMALLY CLOSED configuration See Connecting Leads to a Spring Clamp Terminal Block page 19 The three terminal points for the relay output are located at the bottom left of the terminal blo...

Page 27: ...Power Supply The unit can be reset by turning off the power and then turning it on again To reset a unit by removing the power supply 1 Turn off or disconnect the power to the unit 2 Turn on or reconn...

Page 28: ...ion Manual 16 Appendix The appendix contains the following sections Technical Specifications page 17 Connecting Leads to a Spring Clamp Terminal Block page 19 Troubleshooting page 20 NO to NC Relay Co...

Page 29: ...Frame Rate MPEG 4 SP Up to 25 30 fps PAL NTSC for all resolutions Rate Control Option CBR 128Kbps 4Mbps VBR Storage on the Edge 3 800 Mb 475MB event recording Network Ethernet IEEE 802 3 802 3U 1 x Et...

Page 30: ...to 60 C 32 to 140 F Operating Humidity 5 to 95 non condensing Certifications Safety UL 60950 1 2007 IEC 60950 1 2005 Ed 2 A1 2009 A2 2013 EN 60950 1 2006 Ed 2 A11 2009 A1 2010 A12 2011 A2 2013 CAN CSA...

Page 31: ...To connect a wire to the spring clamp terminal block 1 Strip the insulation form the end of each wire that is to be connected to the terminal block Approximately 1 cm 2 54 of wire should be exposed 2...

Page 32: ...Connecting the Unit to the Network The IP address responds to a ping on the network from the workstation but does not show in the DNA application Disconnect the unit s Ethernet 10 100 port or turn th...

Page 33: ...at the firewall analysis or blocking is not interfering with the video stream and supports the required ports and communication protocols Alarm inputs are not working Check the unit settings to confir...

Page 34: ...er ON o Action Activate relay contact continuous ON Event 2 Triggering Event Detection Alarm according to your configuration o Action 1 Activate relay contact continuous OFF immediately o Action 2 Act...

Page 35: ...0 Fax 44 0 1494 446928 info uk dvtel com INDIA AND SAARC GULF REGION DVTEL India Pvt Ltd 303 SSR Corporate Park Mathura Road Faridabad 121002 Haryana India Tel 91 129 431 5031 Fax 91 129 431 5033 info...

Page 36: ...Call Us or Visit Our Showroom 1300 737 998 3 172 The Entrance Rd Erina...