Operating and Maintenance Instructions
EN
LC.2 – LC.4 – LB.5 – LB.6 – LB.8 – LC.12 – LC.20
6
8702036 – 12/04/2016 – R.7
www.dvp.it
3.3
DIMENSIONS AND CHARACTERISTICS
3.3.1
Model: LC.2 – LC.4
B
A
A
Intake
3
Information plate
7
Oil drain plug
B
Air outlet
4
Attachment point
8
Motor rating plate
1
Motor fun guard
5
Oil filler plug
Only present on special versions
2
Terminal board
6
Oil sight glass
TECHNICAL SPECIFICATIONS
LC.2
LC.4
50 Hz
60 Hz
50 Hz
60 Hz
Inlet capacity
m³/h
2
2,5
4
4,8
Final pressure (Abs.)
mbar - hPa
10
2
Max inlet pressure for water vapour
mbar - hPa
- - - -
Max water vapour pumping rate
kg/h
- - - -
Motor power
kW (1
~
/ 3
~
)
0,12 / 0,12
0,15 / 0,15
0,12 / 0,12
0,15 / 0,15
Nominal r.p.m.
n/min
2800
3300
2800
3300
Noise level (UNI EN ISO 2151) (K 3dB)
dB(A)
48
52
48
52
Weight
kg (1
~
/ 3
~
)
5,4 / 5,4
Type of oil
cod. DVP
BV32 (SW40)
Oil quantity
dm³
0,065
Pump Intake / Outlet
Ø9mm (1/8″G) / - - -
Continuous-duty working renge (Abs.)
mbar - hPa
500 ÷ 10
- - - -
Operating temperature (room temp. 20°C)
°C
50 ÷ 55
55 ÷ 60
50 ÷ 55
55 ÷ 60
Required room temp. for place of installation
°C
12 ÷ 40
Ambient temperature for storage/transport
°C
-20 ÷ 50
MAX humidity / altitude
80% / 1000m a.s.l. *
(*) Please contact the Manufacturer if environmental conditions are different from those prescribed.