Operating and Maintenance Instructions
EN
LC.2 – LC.4 – LB.5 – LB.6 – LB.8 – LC.12 – LC.20
9
8702036 – 12/04/2016 – R.7
www.dvp.it
3.3.4
Model: LC.12
B
A
A
Intake
3
Oil sight glass
7
Motor rating plate
B
Air outlet
4
Oil filler plug
8
Motor fun guard
1
Attachment point
5
Information plate
Only present on special versions
2
Oil drain plug
6
Terminal board
TECHNICAL SPECIFICATIONS
LC.12
50 Hz
60 Hz
Inlet capacity
m³/h
12
14
Final pressure (Abs.)
mbar - hPa
2
Max inlet pressure for water vapour
mbar - hPa
35
Max water vapour pumping rate
kg/h
0,3
Motor power
kW (1
~
/ 3
~
)
0,45 / 0,37
0,55 / 0,45
Nominal r.p.m.
n/min
2800
3300
Noise level (UNI EN ISO 2151) (K 3dB)
dB(A)
62
64
Weight
kg (1
~
/ 3
~
)
14,0 / 12,5
Type of oil
cod. DVP
BV32 (SW40)
Oil quantity
Min÷Max dm³
0,30 ÷ 0,40
Pump Intake / Outlet
“G
1/2
Continuous-duty working renge (Abs.)
mbar - hPa
400 ÷ 2
Operating temperature (room temp. 20°C)
°C
60 ÷ 65
65 ÷ 70
Required room temp. for place of installation
°C
12 ÷ 40
Ambient temperature for storage/transport
°C
-20 ÷ 50
MAX humidity / altitude
80% / 1000m a.s.l. *
(*) Please contact the Manufacturer if environmental conditions are different from those prescribed.