4. GENERAL INFORMATION OF THE PRODUCT

4.1 General Specifications of the Product

 

The control board you have purchased is designed based on microcontroller.

 

All of the control operations on the panel are done electronically and stored in memory.

 

The electronic board in the control panel is produced with high-tech SMD material.

 

SMD led lamp and LCD screen with minimum energy consumption are used as indicators.

5. FRONT PANEL DESCRIPTION AND USE

4.2 Technical Specifications of the Product

 

16 Bit microcontroller designed.

 

248Mhz running frequency.

 

2X16 character LCD (Liquid Crystal Display).

 

Auto test feature.

 

Auto test selenoid valve output.

 

3-phase voltage reading and display on LCD.

 

Voltage protection, possibility to enter the lower and 

upper settings.

 

Pump current reading and display on LCD.

 

Current protection, possibility to enter the lower and 

upper settings.

 

Pump circuit,fault and ready to see the status scrren. 

 

Recognition mode to calculate the pump current. 

 

Possibility to limit te engagement number of the 

pumps 1 hour.

 

Ability to determine the reset time at automatic 

resetting.

 

Ability to reset automatically in error cases and to 

set the reset number.

 

Automatic-manuel selection.

 

Manuel operation when pressing the test button at 

manuel.

 

Protection agains dry operation without floater ans 

SSR control.

 

Protection agains dry operation without moment 

control.

 

Screen to see all the error conditions.

 

Pressure transmitter input and use.

 

Pressure transmitter to monitor the measured value LCD.

 

To adjust the set pressure value.

 

Tracking the operation time of each pump.

 

The actual run time depends on te co-aging.

 

All pumps belonging to the PTC protection.

 

Waste water to be used as panel (menu option).

 

Waste water panel water leak terminal.

 

Password protection against unauthorized 

interference. 

 

Fault recording 20 takes memory.

1. 

2x16 LCD screen.

2. 

Up arrow key to move up in the menu ont main 

screen and provides paging.

3. 

Down arrow key to move down in the menu 

provides.

4. 

Set key to enter the menu and used the changes 

made in the menu.

5.

 ESC key to to return to the menu and the menu   

 before a transacton is allowed rise.

6. 

Automatic run led.

7. 

Auto - Manuel select button.

8. 

Manual Run button.

9. 

Lights when pressure switch is start.

10. 

Error lihgt.

TEST

TEST

 AT

MN

 AT

MN

Auto-2

Pump-2

Auto-3

Pump-3

S2

S3

A2

A3

P-2

P-3

BKP-3

Control Panel

TEST

 AT

MN

Auto-1

Pump-1

S1

A1

P-1

1

2

3

4

5

6

7

8

9

10

Summary of Contents for HYDROPHORE

Page 1: ...INSTALLATION MAINTENANCE and OPERATION GUIDE HYDROPHORE CONTROL PANEL...

Page 2: ...ORE CONTROL PANEL INSTALLATION MAINTENANCE and OPERATION GUIDE www duyarpompa com Control panels to get the best results this manual information must read carefully This manual all your problems can h...

Page 3: ...TRANSPORT STORAGE MONTAGE 3 1 1 Transfer 3 1 1 Transport 3 1 3 Storage 3 1 4 Montage 3 2 OPERATING 3 3 MAINTENANCE 3 3 1 Monthly Maintenance 3 4 GENERAL INFORMATION OF THE PRODUCT 4 4 1 General Speci...

Page 4: ...ble damaged and torn Do not place heavy objects on the power cord and do not make an operation on the cable or injure Cables may be damaged and may cause a fire or electric shock In such cases please...

Page 5: ...ld be checked for any damage during transport If the clipboard contains a damaged or missing damage assessment report should be given written information to the shipping company our company 1 3 Storag...

Page 6: ...ime at automatic resetting Ability to reset automatically in error cases and to set the reset number Automatic manuel selection Manuel operation when pressing the test button at manuel Protection agai...

Page 7: ...n settings menu with the help of the button the past fault information is highlighted and by pressing the down arrow button the most recent fault of the device always moves to the first place A total...

Page 8: ...Reset 2 It is the reset number setting Salt Ability to limit the number of pumps on and off in 1 hour Pump Change It is the changeover time setting for pumps operating in circulation mode The automati...

Page 9: ...ction Insulation Assembly Protection Class Working Altitude PART NAME 230 V 380 VAC 50 60Hz 6VA 20 C to 55 C 10 500 V AC 1 1 30 sec 2 X 16 LCD Screen and Leds Terminal Connection 5 A 250 VAC Resistive...

Page 10: ...E SWITCH FLOATER 6 7 8 3 4 5 2 1 CONTROL PANEL SELENOID U V W X Y Z 17 18 16 15 N COM U V W X Y Z 14 11 12 13 10 9 ERR L1 L2 L3 MAIN 380V AC 50 60Hz PRESSURE SWITCH FLOATER 6 7 8 3 4 5 2 1 CONTROL PAN...

Page 11: ...vibration storage physical collisions damage and malfunction caused by chemical factors and environmental conditions 6 Fire lightning floods earthquakes and other natural disasters damage and malfunc...

Page 12: ...2021 11 1 WE ARE SENSITIVE TO LIFE...

Reviews: