Installer’s Guide
Electric Boosted Solar
17
H3163 025247 Rev. C
• Connect the anti-frost valve to the
top collector connection, on the
opposite collector to where the
thermowell/air bleed valve is installed.
• Ensure the valve is pointing down the
collector towards the gutter, parallel
to the collector.
Flashing
Step 19
• As per local authority regulations,
use an approved method of flashing
on the flow and return lines, e.g.
Dektite or lead collars.
• Where flow and return lines penetrate
the roof surface, the penetration
must occur on the high side of the
roof profile, not in the valley.
• Seal the roof penetration with
a flexible waterproof flashing.
We recommend the use of the
appropriate Dektite brand solar
flashing (available for either tile or
steel roofs).
Anti-Frost Valve
Anti-Frost Valve must
point towards the gutter,
parallel to the collector
Flexible
waterproof
flashing
Roof penetration must
be on high side of tile