Dux 135DC5N Owner'S Manual Download Page 5

Owner’s Manual – Prodigy 4 & 5

3

H3109    3109    Rev. L

Installation Requirements

Water Heater Support:

The water heater must be installed on a 
flat, solid, non-combustible supporting 
surface. The weight of the water heater 
should not cause deformation to any 
part of the building structure.
It is recommended that a plinth is 
installed under the water heater.
The water heater must be installed 
plumb and level.
The water heater must also be secured 
to a durable structure using the wall 
brackets supplied loose with the water 
heater. Note that the gas or water 
pipework must not be used to support 
the water heater.
The wall brackets are designed to be 
installed on each side of the water 
heater with the long leg against the side 
of the water heater and the short leg 
against the wall. The brackets should be 
located near the top of the water heater, 
approximately in line with the Outlet 
and Relief Valve sockets. Note that 
once installed, the brackets should not 
obscure any labels on the water heater.
The brackets should be fixed to the wall 
with suitable fasteners and fixed to the 
water heater with the self drilling screws 
provided.
 

Water Supply:

This water heater has been 
manufactured to suit the water 
conditions of most Australian 
metropolitan supplies.
Please note that certain water supplies 
can have a detrimental effect on the 
water heater and its life expectancy. If 
you are unsure about the water supply 
you can obtain information from the 
local water supply authority.
The water heater is designed for use in 
areas where the Total Dissolved Solids 
(TDS) content of the water supply is 
less than 2500 mg/L. The Tank Failure 
Warranty does not apply in areas where 
the TDS exceeds 2500 mg/L.
In areas where the TDS exceeds 
600mg/L it is possible that the 
magnesium alloy anode (supplied in 
standard water heaters) may become 
overreactive. To alleviate this, the 
magnesium anode should be replaced 
with an aluminium alloy anode. 
Aluminium alloy anodes are available 
from your local Dux Supplier.
Water can also be very corrosive, the 
measure of this is the saturation index. 
If the water saturation index is greater 
than 0.40, an expansion control valve 
should be fitted. Please consult Dux 
After Sales and Service for advice if 
required.

Summary of Contents for 135DC5N

Page 1: ...and transit protection from the heater before installation Dispose of the packaging responsibly using re cycling facilities where they exist H3109 3109 Rev L 4 Star Models 135ZB4N 135ZB4P 170ZB4N 170Z...

Page 2: ...ts 1 Specifications 4 Plumbing Connections 5 Gas Connection and Filling 7 Lighting the Water Heater 8 Shut Down and Draining 9 Testing 10 Owner s Information 11 System Maintenance 13 Considering a Ser...

Page 3: ...vailable Dux recommends that installations conform to AS NZS 3500 4 Note for Victoria This water heater must be installed by a licensed person as required by the Victorian Building Act 1993 Only a lic...

Page 4: ...ommon clearance requirements are set out below At least 300 mm below any eaves balconies or other projections Note that at least half the height of the water heater is recommended as clearance to prov...

Page 5: ...fixed to the wall with suitable fasteners and fixed to the water heater with the self drilling screws provided Water Supply This water heater has been manufactured to suit the water conditions of mos...

Page 6: ...ressure Min 1 13 kPa 2 75 kPa 1 13 kPa 2 75 kPa Gas Supply Pressure Max 3 50 kPa 3 50 kPa 3 50 kPa 3 50 kPa Nominal Dimensions 135L 170L A Overall Height mm 1600 1895 B Outlet Height mm 1325 1620 C In...

Page 7: ...to enable connection of the water heater to supplementary energy sources such as solar panels or slow combustion stoves Refer to AS NZS 3500 4 for guidance on these types of installations Fit the insu...

Page 8: ...y the relevant Authority Plastic pipes or fittings shall not be used between the isolating valve and the inlet See the diagram below for details Water Supply Pressure This water heater is designed for...

Page 9: ...e before the connections are completed The grommet must then be clipped into the case A union should be used to connect the gas pipe to the RP DN15 socket on the gas control valve Ensure that the unio...

Page 10: ...b depressed repeatedly press the igniter button for up to 40 seconds until the pilot flame ignites Note it is not possible to depress the control knob fully if the gas control valve has activated its...

Page 11: ...heater by carrying out the steps listed at left 2 Gently operate the easing lever on the Pressure Temperature Relief PTR Valve to release the pressure in the water heater 3 Disconnect the cold water...

Page 12: ...the thermostat knob to the off position and turn off the gas isolation valve 7 Disconnect the manometer and replace the screw removed at step 2 Test the Gas Test Point Pressure For correct operation...

Page 13: ...Relief PTR Valve must be installed directly into the top socket marked RELIEF VALVE The PTR Valve rating is shown on the compliance plate The valve must not be tampered with or removed The water heat...

Page 14: ...ot expecting to need hot water for more than a few days the control knob on the gas control valve thermostat can be set to the pilot position to conserve energy Alternatively the water heater can be s...

Page 15: ...r than this personally inspecting or servicing any part of the water heater is not recommended Annual Service This service should only be carried out by a licensed tradesperson We recommend your local...

Page 16: ...water tap A small leak can waste a large quantity of hot water Replace faulty tap washers and arrange for your plumber to rectify any leaking pipe work Is the Pressure Temperature Relief Valve discha...

Page 17: ...er parts 1 year The benefits provided to you by this warranty are in addition to any other rights and remedies available to you under the Australian Consumer Law Parts and Labour Warranty Dux Manufact...

Page 18: ...ation of Dux to make the water heater accessible for repair or replacement Where the Dux water heater is located outside the metropolitan area of a capital city and is more than 100km from a Dux offic...

Page 19: ...ailure If Dux fails to meet a guarantee under the ACL your remedy for such failure may be limited to any one or more of the following replacement of the water heater repair of the water heater refundi...

Page 20: ...warranty Please Register Your Water Heater Please take a moment to fill out your details for warranty registration at This will ensure all your current details are registered with us for prompt warra...

Reviews: