Considering a Service Call?

It is recommended that the following 
points be reviewed before making a 
service call:

No Hot Water:

Confirm the pilot is alight. If it is not, see 
Lighting the Water Heater on page 8. 

High Gas Bills or Insufficient Hot 

Water:

•  Consider that often the hot water 

usage of showers, washing 
machines and dishwashers can 
be under estimated. Review these 
appliances to determine if the daily 
usage is greater than the capability 
of the water heater.

•  If necessary check the shower flow 

rates with a bucket, measuring 
the amount of water used over a 
period of time. If it is not possible 
to adjust water usage patterns, an 
inexpensive flow control valve can 
easily be fitted to the shower outlet.

•  Is the water heater the correct size 

for the requirements? Sizing details 
are available from your Dux supplier.

•  Is there a leaking hot water pipe or 

dripping hot water tap? A small leak 
can waste a large quantity of hot 
water. Replace faulty tap washers 
and arrange for your plumber to 
rectify any leaking pipe work.

•  Is the Pressure & Temperature Relief 

Valve discharging too much water? 
See below.

Continuous Trickle of Water from 
Pressure & Temperature Relief (PTR) 
Valve:

This is most likely due to a build up of 
foreign matter. In this case, try gently 
raising the easing lever on the PTR Valve 
for a few seconds, then release gently. 
This may dislodge a small particle of 
foreign matter and rectify the fault.

Water Discharge from PTR Valve:

It is not unusual for a small quantity of 
water to discharge during the heating of 
water in the storage tank. The amount 
of discharge will depend on hot water 
usage and the size of the storage tank.
As a guide, it will discharge about 2% of 
the volume of the water heated. 
Continuous leakage of water from the 
PTR Valve may indicate a problem with 
the water heater. Shut down the water 
heater and contact Dux After Sales and 
Service.

If after checking the above points, 

the problem has not been identified, 

please contact Dux After Sales and 
Service.

Summary of Contents for 135DC5N

Page 1: ...and transit protection from the heater before installation Dispose of the packaging responsibly using re cycling facilities where they exist H3109 3109 Rev L 4 Star Models 135ZB4N 135ZB4P 170ZB4N 170Z...

Page 2: ...ts 1 Specifications 4 Plumbing Connections 5 Gas Connection and Filling 7 Lighting the Water Heater 8 Shut Down and Draining 9 Testing 10 Owner s Information 11 System Maintenance 13 Considering a Ser...

Page 3: ...vailable Dux recommends that installations conform to AS NZS 3500 4 Note for Victoria This water heater must be installed by a licensed person as required by the Victorian Building Act 1993 Only a lic...

Page 4: ...ommon clearance requirements are set out below At least 300 mm below any eaves balconies or other projections Note that at least half the height of the water heater is recommended as clearance to prov...

Page 5: ...fixed to the wall with suitable fasteners and fixed to the water heater with the self drilling screws provided Water Supply This water heater has been manufactured to suit the water conditions of mos...

Page 6: ...ressure Min 1 13 kPa 2 75 kPa 1 13 kPa 2 75 kPa Gas Supply Pressure Max 3 50 kPa 3 50 kPa 3 50 kPa 3 50 kPa Nominal Dimensions 135L 170L A Overall Height mm 1600 1895 B Outlet Height mm 1325 1620 C In...

Page 7: ...to enable connection of the water heater to supplementary energy sources such as solar panels or slow combustion stoves Refer to AS NZS 3500 4 for guidance on these types of installations Fit the insu...

Page 8: ...y the relevant Authority Plastic pipes or fittings shall not be used between the isolating valve and the inlet See the diagram below for details Water Supply Pressure This water heater is designed for...

Page 9: ...e before the connections are completed The grommet must then be clipped into the case A union should be used to connect the gas pipe to the RP DN15 socket on the gas control valve Ensure that the unio...

Page 10: ...b depressed repeatedly press the igniter button for up to 40 seconds until the pilot flame ignites Note it is not possible to depress the control knob fully if the gas control valve has activated its...

Page 11: ...heater by carrying out the steps listed at left 2 Gently operate the easing lever on the Pressure Temperature Relief PTR Valve to release the pressure in the water heater 3 Disconnect the cold water...

Page 12: ...the thermostat knob to the off position and turn off the gas isolation valve 7 Disconnect the manometer and replace the screw removed at step 2 Test the Gas Test Point Pressure For correct operation...

Page 13: ...Relief PTR Valve must be installed directly into the top socket marked RELIEF VALVE The PTR Valve rating is shown on the compliance plate The valve must not be tampered with or removed The water heat...

Page 14: ...ot expecting to need hot water for more than a few days the control knob on the gas control valve thermostat can be set to the pilot position to conserve energy Alternatively the water heater can be s...

Page 15: ...r than this personally inspecting or servicing any part of the water heater is not recommended Annual Service This service should only be carried out by a licensed tradesperson We recommend your local...

Page 16: ...water tap A small leak can waste a large quantity of hot water Replace faulty tap washers and arrange for your plumber to rectify any leaking pipe work Is the Pressure Temperature Relief Valve discha...

Page 17: ...er parts 1 year The benefits provided to you by this warranty are in addition to any other rights and remedies available to you under the Australian Consumer Law Parts and Labour Warranty Dux Manufact...

Page 18: ...ation of Dux to make the water heater accessible for repair or replacement Where the Dux water heater is located outside the metropolitan area of a capital city and is more than 100km from a Dux offic...

Page 19: ...ailure If Dux fails to meet a guarantee under the ACL your remedy for such failure may be limited to any one or more of the following replacement of the water heater repair of the water heater refundi...

Page 20: ...warranty Please Register Your Water Heater Please take a moment to fill out your details for warranty registration at This will ensure all your current details are registered with us for prompt warra...

Reviews: