background image

Island Clean Air Filters

 

Each ICA filter has been engineered to provide maximum filtration with calibrated 
velocities to capture harmful airborne particulates. Using non-ICA branded filters in 
the Duster 3000 Downdraft will: not seal properly, impede airflow, jeopardize 

HPSOR\HHVDIHW\LQWHUIHUHZLWKWKHVHQVLWLYHFDOLEUDWLRQRIWKHXQLW¶VPRQLWRULQJ

system, and void the warranty. 

 

*** Proper Cleaning & Maintenance Will Prolong Filter Life *** 

 
Stage 1: Green Pre-Filter Pad (Part #11703) 

x

  Filters dust and paint overspray. 

x

  Clean daily or weekly. Do not pressure wash. 

x

  Vacuum the front of the green pad. Remove from intake filter and blow with 

compressed air. 

x

  It has an approximate life of 2-3 months. 

 

Stage 2: Pleated Intake Filter (Part #11205) 

x

  Filters dust and paint overspray. 

x

  Clean daily or weekly. Do not pressure wash. 

x

  Remove from machine and remove green pad. Blow yellow pleated side with 

compressed air and vacuum white pad. 

x

  It has an approximate life of 6-9 months. 

 

Stage 3: Activated Carbon Filter (Part #11209) 

x

  Absorbs VOCs, fumes, and odors. 

x

  Not cleanable. To improve fume absorption efficiency, shake monthly. 

x

  Replace when it weighs over 15lbs. Typical life of 9-12 months. 

 

Stage 4: Viledon Top Pocket Filter (Part #11207) 

x

  Filters smaller particles down to 3 microns. 

x

  Not cleanable. As it gets dirty, it will slowly change color from white to dark gray. 

x

  With proper maintenance of the other three stages, this filter may last up to 18-24 

months. 

 

Accessing the Viledon Top Pocket Filter

 

x

  Turn off the unit and unplug from electrical outlet.

 

x

  Remove plenum from Lexan shroud.

 

x

  Hang the plenum on gray support rod.

 

x

  Unlatch the four quick release latches and lift the Lexan 

shroud off.

 

x

  The Viledon is now accessible and can be replaced.

 

x

  When installed properly, all five pockets of the Viledon 

should be visible from the front of the unit and be inflated 
and vertically aligned.

 

x

  When reinstalling the Lexan shroud, ensure that the 

pockets of the Viledon are not pinched between the body 
and shroud. 

 

 

Summary of Contents for 3000 DOWNDRAFT

Page 1: ...Operations Maintenance Manual IMPORTANT READ BEFORE OPERATING MACHINE Duster 3000 DOWNDRAFT Model 00301 Mobile Prep Station ...

Page 2: ...el 8 Digital Airflow Monitor 9 PVC Support Rod 10 Quick Release Latches 11 Top Filter Neoprene Seal 12 Intake Filter Seals 13 Stage 4 Viledon Top Pocket Filter 14 Stage 1 UHHQ 3UH Filter Pad 15 Stage 2 Pleated Intake Filter 16 Stage 3 FWLYDWHG DUERQ LOWHU 17 Downdraft Plenum 18 Discharge Diffuser Black 19 Velcro Strips 20 Velcro Tabs ...

Page 3: ...he carbon filters are not pinched between the filters x Secure the intake filters with the Velcro tabs located on both sides of each filter Correct Incorrect x Proper sealing of the intake filters will prevent dirty air from bypassing the metal framed intake filters Improper sealing will plug up the carbon filters and the Viledon top pocket filter Step 3 Plug in the Duster 3000 Downdraft x Locate ...

Page 4: ... or replacing x The Duster 3000 Downdraft will automatically shut down when the yellow light comes on to prevent permanent damage to the motor x The yellow light has been factory preset to go off around 2000 CFM or lower Positioning the Duster 3000 Downdraft For the greatest effectiveness position the unit so that the downdraft plenum is directly above your work area This will ensure that dust or ...

Page 5: ...ir and vacuum white pad x It has an approximate life of 6 9 months Stage 3 Activated Carbon Filter Part 11209 x Absorbs VOCs fumes and odors x Not cleanable To improve fume absorption efficiency shake monthly x Replace when it weighs over 15lbs Typical life of 9 12 months Stage 4 Viledon Top Pocket Filter Part 11207 x Filters smaller particles down to 3 microns x Not cleanable As it gets dirty it ...

Page 6: ...es can be wiped with warm water and detergent avoiding the electronic components Downdraft Plenum Maintenance x The downdraft plenum can be cleaned Remove from unit clean with soap and water rinse with clean water air dry and reinstall The discharge diffuser on the top of the plenum can also be blown out with compressed air x Do not machine wash or dry x Small rips or tears can be repaired by remo...

Page 7: ...cord PLUG CAP is to be connected to receptacle located in non hazardous area non classified area Warranty In order to validate your warranty the Warranty registration card must be completed and returned to ICA All products made by ICA are warranted to be free of defects in materials and workmanship for a period of one 1 year from the date of original purchase This limited warranty does not include...

Page 8: ...Business Park Vancouver BC V5X 4N6 Canada Tel 604 322 D 8674 PDLO LQIR LVODQGFOHDQDLU FRP HEVLWH www islandcleanair com Committed to Green ATEX Approved CSA Certified Air Resources Board Printed in Canada Specifications subject to change without notice March 2021 ...