CAUTION
The machine must never be tipped without first emptying the container.
The filter bag in the container should be replaced when it is filled to max 1/3. We
recommend that you always have the filter bag in the machine to avoid unnecessary
wear. Only use genuine bags.
Service/Maintenance
The machine must be turned off and unplugged before cleaning and maintenance.
The water pump can easily be dismantled and placed on the floor before cleaning.
Only use genuine filter bags. Regularly check the power cord for damage.
The DC 50, 75 W must be tested and serviced at least once a year as it is used with
wet materials.
Worn parts must be replaced. Never risk functionality and service life. Only use
genuine parts. The machine’s fan is maintenance-free.