Operation
DC 1800:
Connect the unit to a suita-
ble power source, note requirements
on the ID plate. If an extension cord is
to be used, only waterproof cords are
acceptable.
DC 1800 Autostart:
Connect the sub-
ject electric tool to the electrical outlet on
unit. Set the selector switch to the AUTO
position. Th
e unit will start automatically
when the subject tool is started. For manu-
al start of the unit, set the selector switch
to the MAN position.
The DC 1800 is equipped with a
fi
lter
indication lamp that indicates when
the
fi
lter needs cleaning or chang-
ing. The
fi
lter is genereally cleaned
once or twice daily during normal continuous opera-
tion. The unit must be in operation to perform
fi
lter
cleaning. Loose the tube from the suction pipe and
press the plastic cage against the black stop head
on the exhaust channel
so that maximum pressure
is created in the cyclone.
Open the port on the side o the unit three to six
times. This reverse pulse of air cleans the
fi
lter.
The machine can be used both with or without col-
lection sack.
The collection sack should only be changed after
the cleaning of the
fi
lters. The collection sack must
be tied off when it is removed from the container.
Use only original Dustcontrol spare parts. There
should not be any fold on the container border.
The tightness make that the sac does not being
sucked.
When remounting the motor top and the cyclone
on the container the hose inlet should be pointed
according to the picture beside.
For best result:
-Secure that no air is between the bag and the
barrel when you apply the bag.
-Secure that no air is leaking between the bag
and the barrel when you are using the machine.