Machine service
T
he DC 11-module should be tested and
maintained once a year. Worn parts must be
changed.
Do not jeopardise function and lifetime. Use only
Dustcontrol spare parts.
During maintenance and service the machine
must be switched off at the main switch.
Lubrication (1)
(for the DC 11-Module S and
P models)
The turbopumps bearing should be lubricated
at least once a year with lithium saponi
fi
cated
roller bearing grease, Part No 9683.
• Release
rear bearing cooling
fl
ange.
•
Check the grease condition and
fi
ll until 2/3
of the cover volume.
• Change
the
O-ring, Part No 4789, and re-
mount the cooling
fl
ange.
Filter change (3)
It is important that the
fi
lter is changed when it can
no longer clean ef
fi
ciently. The space between
the changes depends on which type of dust you
extract and the air
fl
ow the
fi
lter is exposed to.
The
fi
ne
fi
lter should be changed at least once per
year. Only a Dustcontrol
fi
lter should be used. Use
breathing protection during the
fi
lter change. Do
not expose unprotected persons to harmful dust.
1. Turn off and lock the power disconnect switch.
2. Use breathing protection
3. Disconnect the top of the cyclone
4. Disconnect the locking ring for the
fi
lter.
5. Lift out the
fi
ne
fi
lter and seal it in a plastic
bag.
6. Lift in the new
fi
lter cartridge
7. Re-connect
the
fi
lter locking ring
8. Lift the top on and connect.
Service DC Green System
DC Green System (2b):
The function of the sensors should also be check-
ed in conjunction with servicing of the pump.
1. Check the switchover between energy-saving
mode and control mode according to ”Test run-
ning” above.
2. Check the operating pressure when the sys-
tem is in control mode (at least one outlet open).
Service DC 11-Module
If the thermal sensor alarm occurs, the function of
the
fl
ow sensor should be investigated
fi
rst. If the
system does not switch to energy-saving mode
when all the outlets are closed the pump will over-
heat. This fault can be due to the failure of the
fl
ow
sensor to function as it should, to the presence of
e a major leak in the system, or to the extraction
equipment that is being used admitting too little air.
Summary of Contents for 14124x
Page 10: ...Part No 94153 G DC 11 Module 43 Operation DC 11 Module ENGLISH ...
Page 12: ...Part No 94153 G DC 11 Module 45 Technical data DC 11 Module XL 226 5 21 5 1553 72 21 ENGLISH ...
Page 36: ...Part No 94153 G DC 11 Module 69 Change of Discharge collection sack ENGLISH ...
Page 37: ...DC 11 Module 70 Part No 94153 G 2017 03 08 Change of Discharge collection sack ...
Page 38: ...Part No 94153 G DC 11 Module 71 Change of Discharge collection sack ENGLISH ...
Page 43: ...DC 11 Module 208 Part No 94153 G 2017 03 08 Drift DC 11 Module ...
Page 70: ...Part No 94153 G DC 11 Module 235 Change of Discharge collection sack DANSK ...
Page 71: ...DC 11 Module 236 Part No 94153 G 2017 03 08 Change of Discharge collection sack ...
Page 72: ...Part No 94153 G DC 11 Module 237 Change of Discharge collection sack DANSK ...