Electrical installation:
•
The connection wiring including potential equalisation (potential equalisation rail is fitted to the
frame) for the whirlpool must be installed in accordance with the provisions of your local
electricity supplier and observing DIN VDE 0100-701. The connections must be established by a
l
icensed electrician.
•
The protected areas must be precisely adhered to
•
Parts of the device which contain live parts (excluding parts with protected low voltages
up to 12V) must be inaccessible to people using the bath.
•
The connection is only permitted in area 3, outside protected areas 0 to 2
Electrical connections:
•
Caution: All assembly and disassembly work on the Step-in Spa Music may only be
carried out when de-energised and in a dust-free condition!
•
The complete system must be connected through a residual current device (RCD breaker) with
a rated residual current of not more than 30 mA
•
The complete system must also be permanently connected to the mains via an all-pole
mains isolation switch (in accordance with monitoring category III) which provides a full
disconnection, via permanently fixed wires and fused at 16A.
•
Switch panel to bathtub connection lead: at least F3Gx1.5 (NYMHY 3 x 1.5 mm2 old)
•
The Step-in Spa Music must be switched off when not in use or when being serviced
ElEctrIcal InStallatIon:
PROTECTION AREAS IN ACCORDANCE WITH DIN VDE 0100-701
Summary of Contents for ShowerLux Step-in Sparkling + Music
Page 9: ...5 DN 50 G G AG DIN ISO 228 DN 50 B B 6 220V A B A B 9 Wannenmontage...
Page 19: ...5 DN 50 G G AG DIN ISO 228 DN 50 B B 6 220V A B A B 19 Installation Instructions...
Page 29: ...5 DN 50 G G AG DIN ISO 228 DN 50 B B 6 220V A B A B 29 Instruction de montage...
Page 39: ...5 DN 50 G G AG DIN ISO 228 DN 50 B B 6 220V A B A B 39 IstruzionE di montaggio...
Page 42: ...www duscholux com...