EN
EN
4 InstallatIon
notE
risk of breakage
➜
Do not place PanElle Enlight on the edges.
4.1 scope of supply, accessories and tools
required
➜
See figures
,
,
.
➜
Check the delivery for damage and completeness
before assembly.
• The accessories for power connection and
operation are only supplied for the version
ordered (figure
, options
1 to 3
).
• Duscholux does not accept any liability for
damage due to the installation of clearly
incomplete or defective products.
4.2 Electrical connection
protected areas in rooms with bath or shower equipment
in accordance with dIn VdE 0100-701
• Only install the electrical connection (230 V) outside
protected areas 0-2 in protected area 3 (figure 1 ).
• Provide a power source to supply PanElle Enlight (24 V)
outside protected areas 0-1.
• In protected area 1, only install PanElle Enlight with an
operating voltage of 24 V DC.
preparing the electrical connection
➜
See figures
2 and 3
.
➜
See “electrical installation” check list.
• The PanElle Enlight connection must be established by
an electrician in accordance with the local provisions,
to prevent danger due to electrical currents.
• All assembly and disassembly work on PanElle Enlight
must be performed whilst in a de-energised state.
• Connect the complete system via a residual current
device (RCD breaker) with a rated differential current of
max. 30 mA.
4.3 assembly
Preconditions (figure
7 and 9)
• Degrease:
–
Rear side of PanElle Enlight
–
Application surface for PanElle Enlight (wall)
–
Aluminium profile
danGEr oF ElEctrIc sHock
danGEr oF WatEr damaGE
➜
Make sure that no power or water lines run
through the drilling area.
The fastening material supplied is
fundamentally suitable for all application
surfaces. Preconditions: The application
surfaces are firm, dry, abrasion-resistant and
free of grease. In case of doubt, use an adhesive
primer.
Establishing the electrical connection
➜
See figures
4
and
5
.
danGEr oF ElEctrIc sHock
➜
Make sure the prepared electrical connection
is de-energised.
➜
Make sure that wires do not cross when es-
tablishing the electrical connection.
Testing the electrical connection (before final assembly)
➜
Switch the PanElle Enlight lighting on and off.
Fit and grout/silicone seal the panElle Enlight. If panElle
Enlight is installed in a wet zone, the edges/openings
must be fully silicone sealed (water and electrics).
➜
See figure
17
.
notE
danger of leaks or mould formation
➜
Before grouting/silicone sealing, it is necessary
to de-grease and dry all contact areas.
➜
Only use plumbing silicone in accordance with
EN15651-3.
4.4 testing
➜
Test the electrical functions of PanElle Enlight,
see instructions for the respective controller.
4.5 cleaning
notE
damage to panElle Enlight
➜
Do not use any cleaning products that are abrasive,
contain solvents or chlorine, or any aggressive acids
or bases.
➜
Observe the information on cleaning and care.
3
DUSCHOL
UX
6
DUSCHOL
UX