4
Technical data
Electrical data
5286100036
Nominal voltage
V
230
Mains frequency
Hz
50
60
Nominal current at 8 bar (0.8 MPa)
A
7.7
7.2
Motor protection
Motor winding overheat protector
Speed
rpm
1390
1650
Type of protection
IP20
Mains fusing *
A
16
Max. permissible mains impedance in
accordance with EN 61000
‑
3
‑
11
W
0.2069
*
Circuit breaker fuse characteristics C in acc. with EN60898-1
General data
Pressure tank volume
l
20
Suction power, approx.
l/min
260
315
Delivery at 5 bar (0.5 MPa)
l/min
110
126
Pressure build-up phase 0 - 7.5 bar (0 -
0.75 MPa) c.
s
75
-
Duty cycle
%
100 (S1)
Start-up pressure
bar (MPa)
5.5 (0.55)
Cut-off pressure
bar (MPa)
7.5 (0.75)
Cut-off pressure, max. adjustable
bar (MPa)
9.5 (0.95)
Switching hysteresis min.
Switching hysteresis max.
bar (MPa)
bar (MPa)
1 (0.1)
3 (0.3)
Safety valve, maximum permissible oper-
ating pressure
bar (MPa)
10 (1)
Pressure dew point at 7 bar (0.7 MPa) *
°C
£
+5
Dimensions (H x W x D) **
cm
84 x 63 x 60
Weight
kg
59
Noise level ***
dB(A)
56
59
*
Value determined at an ambient temperature of +40 °C
**
Values without accessories and add-on parts
*** In accordance with ISO 3746.
Filter mesh size
Compressor unit intake filter
µm
3
Fine filter for membrane drying unit
µm
3
Sterile filter for membrane drying unit
µm
0.01
Sintered filter for membrane drying unit
µm
35
Product description
8
5286100072L02 1909V005
EN