CONTROL PANEL FUNCTIONS
Engine Overload Indicator Light
If the engine overload indicator light comes on, the generator s wattage
/ amperage capacity has been exceeded by connected electrical
devices or by a power surge. When this occurs, the green AC Pilot
Indicator Light will go off. The engine will continue to run, but the red
Engine Overload Indicator Light will stay on and power will no longer be
supplied to connected electronic devices.
Oil Warning
Indicator
Overload
Indicator
AC Pilot
Indicator
,
How to Correct
1. Disconnect any electronic devices then stop the engine.
2. Reduce the total wattage of connected electronic devices until it is
within the generator’s rated output.
3. Inspect the Air Inlet and Control Panel for any blockage. Remove
blockage if found.
4. Restart Engine.
Fuel Selector Switch
When the Switch is in the Gas position and the Gasoline "On" the
generator is ready to start on Gasoline.
When the Switch is in the LPG position and the Gasoline is "Off" the
generator is ready to start on Gasoline.
Choke Lever
When starting the generator on gasoline, pull out the "Choke" lever to
allow the unit to start. Once started, push the choke back in the allow the
unit to run normally.
Note:
The Choke is not required to start a warm engine
Oil Warning Indicator Light
When the oil falls below the minimum level, the oil warning indicator
light comes on and the engine stops automatically. The engine will not
start u
n
til the proper amount of oil is in the crank case.
Note:
If the oil warning indicator light does not come on and the engine
stalls, turn the Start Switch to “R
U
N” and pull the recoil
starter.
8