STARTING THE GENERATOR (CONTINUED)
Starting the Generator Using Recoil Start
36
Shut breaker off
The breaker is located on the right side of the front power
panel. Flip the breaker down to prevent accidental load
when starting the generator.
1.
Turn gas valve on
Close choke
Turn engine switch to On
The gas valve is located above the recoil start on the bottom
of the fuel tank. Rotate the valve clockwise to the vertical
position to turn on the gas supply.
The choke lever is located above the air filter to the right
of the recoil start. Slide the lever to the left to cut the air
supply and allow more gas into the engine to start.
The key switch is located on the left side of the front power
panel. Insert the key and turn to the on position to start the
generator.
2.
3.
4.