STARTING THE GENERATOR
Shut breaker off
The breaker is located on the right side of the front power
panel. Flip the breaker down to prevent accidental load
when starting the generator.
1.
Starting the Generator
Turn gas valve on
Close choke
Turn engine switch to START
The gas valve is located above the recoil start on the bottom
of the fuel tank. Rotate the valve clockwise to the vertical
position to turn on the gas supply.
The choke lever is located above the air filter to the right
of the recoil start. Slide the lever to the left to cut the air
supply and allow more gas into the engine to start.
The key switch is located on the left side of the front power
panel. Insert the key and turn to the start position to start
the generator. Allow the key to return to the run position
once started.
2.
3.
4.
34
Summary of Contents for XP12000E
Page 2: ......
Page 5: ......
Page 11: ...11 ...
Page 14: ......
Page 22: ...22 ...
Page 30: ...30 ...
Page 38: ...38 ...
Page 46: ...46 ...
Page 49: ...MAINTENANCE LOG Date Generator Hours Maintenance Performed 49 ...
Page 68: ...WIRING DIAGRAM 68 M ...
Page 69: ...69 ...
Page 75: ......
Page 76: ...5800 Ontario Mills Parkway Ontario CA 91764 United States 844 DUROMAX REV XP12000E 07072020 ...