Operating manual part II
© 2010 Dürkopp Adler AG
II-11
L
C
P
Min
Max
Preset Unity
Description
Function module
t
11 00 0
6
0
-
Function of module 1 (X2.30)
0 = No Function;
1 = Additional thread tension;
2 = Switch stitch length;
3 = Single stitch with stitch length switching;
4 = Single stitch backwards with stitch length switching;
5 = Lift/lower roller;
6 = Lift/lower fabric end stop
t
11 01 0
1
0
-
Output of function module 1 (X2.30) inverted
0 = No;
1 = Yes
t
11 02 0
1
0
-
Deactivation of function module 1 after trimming process.
0 = No;
1 = Yes
t
11 30 0
6
0
-
Function of module 2 (X2.20)
0 = No Function;
1 = Additional thread tension;
2 = Switch stitch length;
3 = Single stitch with stitch length switching;
4 = Single stitch backwards with stitch length switching;
5 = Lift/lower roller;
6 = Lift/lower fabric end stop
t
11 31 0
1
0
-
Output of function module 2 (X2.20) inverted
0 = No;
1 = Yes
t
11 32 0
1
0
-
Deactivation of function module 2 after trimming process.
0 = No
1 = Yes
t
11 60 0
6
0
-
Function of module 3 (X2.15)
0 = No Function;
1 = Additional thread tension;
2 = Switch stitch length;
3 = Single stitch with stitch length switching;
4 = Single stitch backwards with stitch length switching;
5 = Lift/lower roller;
6 = Lift/lower fabric end stop
t
11 61 0
1
0
-
Output of function module 3 (X2.15) inverted
0 = No;
1 = Yes
t
11 62 0
1
0
-
Deactivation of function module 3 after trimming process.
0 = No;
1 = Yes
t
11 90 0
999
100
ms
Drive time of output FF3 in the time period t
1
t
11 91 5
100
100
%
Pulse duty ratio in the time period t
1
t
11 92 0,0
600,0
0,0
s
Drive time of output FF3 in the time period t
2
(If you adjust 0s the output FF3 will be driven permanently)
t
11 93 5
100
35
%
Pulse duty ratio in the time period t
2
t
11 94 0
1
0
-
Increasing U
mag
when the output FF3 will be driven
0 = No;