Changing the knives
16
Additional Instructions M-TYPE DELTA - 00.0 - 05/2020
3
Changing the knives
To change the knives, you will need a size 10 Torx screwdriver for the
clamping spring and a 2.5 mm hexagon socket screwdriver for the knife
screws.
Fig. 15: Changing the knives (1)
To change the knives:
1.
Disassemble the throat plate (
Service Instructions
).
2.
Loosen screw (1) and adjusting wheel (2).
3.
Remove the clamping spring (3).
4.
Loosen adjusting wheel (5) and screws (6).
5.
Remove the counter blade (4).
Fig. 16: Changing the knives (2)
(1)
- Screw
(2)
- Adjusting wheel
(3)
- Clamping spring
(4)
- Counter blade
(5)
- Adjusting wheel
(6)
- Screws
⑥
①
②
③
⑤
④
(7)
- Thread-pulling knife
⑦