45
Problem
Potential cause
Solution
See
page
“Hygiene” button flashes.
Hygiene and tempera-
ture circuit stopped manu-
ally.
>
Press the “Hygiene” button.
The “Hygiene” button lights
up, the hygiene and tem-
perature circuit starts.
“Water level too low” is
also displayed.
>
Refill the water until the
water level is about 50
mm above the uppermost jet.
A continuous acoustic
signal sounds.
Heating defective.
>
Please call Customer Ser-
vice.
Foaming
Soap, shampoo, wrong /
too much cleaning / care
agent in bathwater
>
Empty pool, clean and refill. 43
Whirl system does not
start.
Mains switch switched off.
>
Switch on at mains.
Earth leakage current
protection tripped.
>
Check whether the earth
leakage current protection
has tripped.
Otherwise:
>
Please call Customer Ser-
vice.
Water flows out of the vent
valve, while a whirlpool
system is active.
This is normal because the
air valve is vented while
some water escapes.
Water runs out continu-
ously from the vent valve.
Filter fouled
>
Replace the filter.
41
Air valve is wrongly in-
stalled
>
Remove the valve and re-
install as described.
41
Air valve fouled
>
Clean the air valves under
running water.
Air valve defective
>
Replace the air valves and
filter.
41
Remote control does not
respond.
Battery drained.
>
Recharge the remote con-
trol for at least 3 hours.
25
Remote control has
dropped into energy saver
mode.
After having been stored
outside of radio range, the
remote control needs to be
reactivated:
>
Place the remote control on
the charging station.
After 2 seconds, the “Emo-
tion” button lights up.
25