32
ensure the switch is not activated until you are ready to proceed.
> Open the fine filter
(5)
.
> Remove the exchangeable cartridge and dispose of it (microbial contamination!)
> Open the bypass valve at the bottom of the fine filter with the tool supplied, so that
the hygiene and temperature circuit can run empty. (Fig. 5)
> Wait until the water has drained off.
> Close the bypass valve again.
> Clean the air valves in the cover of the fine filter housing under running water.
> Check the operation of the air valves.
> Clean out the fine filter housing with a damp cloth and re-close it (without a new
cartridge).
> Clean the coarse filter insert
(3)
.
> Place the bath cushions around the pool and collapse the relaxing deck.
> Pull the tarpaulin over the pool and the cushions/relaxing deck.
Fig. 5
Start up pool again
Follow steps 1-2 and 4-5 as described in the chapter
“
First Start-up of the Pool
”
. The
operator's panel does not need to be configured again from the start.
10. Cleaning and Maintenance
CAUTION
Detergents can unknowingly affect the hygiene balance of the water.
> Please ensure that detergents do not end up in the pool bathing water.
NOTICE
Damage can occure to the surfaces and the whirl system due to
Summary of Contents for Pool